INSTRUCTION MANUAL
3
REMARKS
• During the shooting it is recommended to keep one hand inside the machine holding the
confetti to avoid all confetti is blown at once. Release the confetti gradually according to
the desired rainfall intensity.
•
Remember that for the machine to STORM BLASTER it is recommended to use cylinders
of liquid CO2 with probe
DISASSEMBLY
•
For disassembly, the hose must be without pressure. For this purpose, close the CO2
bottle and turn on CO2 TAP/VALVE (2) of the machine to release all the gas inside, before
you disconnect the hose.
5. Connect then the high pressure hose (3) of the cone to the bottle adaptor (6) and tighten
with a wrench. It is important to tighten it so that to avoid any leak. Attach the safety cable
from the high pressure hose around to the bottle.
6.
Make sure that the CO2 tap/valve (2) is closed. Open then the CO2 bottle and make sure
there is no leak. If you are not going to use the machine immediately close the bottle of
CO2.
7. Close the FLAP GATE FOR THE CONFETTI (7) and place the confetti you desire to blow
on top of it.
8. Open the tap of the CO2 cylinder and the machine will be ready to run. To shoot, you only
need to open the CO2 TAP/VALVE (2) of the machine. The machine will instantly suck the
confetti and blow it in the air.
GENERAL CAUTION FOR STORM BLASTER
• STORM BLASTER machine has been designed for the effect described. Any other use,
different from the written excludes Oh!FX (CONFETTISHOTS SLU) of liability and warranty.
•
Use always the STORM BLASTER in open spaces or indoors with good ventilation. Never
use it in enclosed spaces without ventilation because the concentration of CO2 can cause
suffocation. If you have doubts about the features of the enclosure use a meter to measure
CO2 concentration.
•
Always use hoses and connections of the high pressure provided by the distributor and
duly certified.
•
During and after the shot, the CONFETTI CONE (1) can get frozen because of the CO2.
Do not touch that part as it can cause burns.
• Do not point directly at anyone at less than 4 meters away. Always keep a safety distance
of 3 meters between the/s machine/s and the public.
• In case of a leak or malfunction, do not attempt to disassemble the machine and contact
the distributor or manufacturer. Any manipulation may exclude the warranty
• Use only the consumables intended for that specific use, and duly certified.
• Only one adult and qualified person must manipulate the machine.