- 1 -
1. General
1.1 LC™ Jumper Connectors
The LC Fiber Optic Simplex and Duplex Jumper Connectors can be used to terminate simplex
and duplex 1.6-mm MiniCord
jumper cords. It is intended for use in Central Offices, Local Area
Networks (LANs), and in patch cords for Premises Distribution Systems such as SYSTIMAX
®
Structured Cabling Systems. The connector can also be used in computer backplane
connections, computer peripheral interconnections, device terminations, and other applications
where quality, small-size, high-density, low-loss, and a low-cost infrastructure are required.
Note: In addition to the simplex and duplex LC jumper connectors for 1.6-mm MiniCord
jumper cords, a Behind-The-Wall (BTW) connector is offered for 0.9-mm buffered fiber.
Installation of the BTW connector is not covered in this customer information product
(CIP). The BTW connector can be used to terminate Outside Plant (OSP) cables as well
as building cables.
When installed on typical fiber, the following performance should be obtained:
Multimode
Insertion loss (avg.) = 0.1 dB
Return loss
≥
30 dB
Singlemode
Insertion loss (avg.) = 0.2 dB
Return loss
≥
50 dB
1.2 Epoxy Consumables
Kit Type (Note)
Kit Number
Comcode
Kit Includes
Multimode
D-182983
108 340 811
Polishing paper, epoxy, and other materials
required to assemble 200 multimode connectors.
Singlemode
D-182977
108 338 591
Polishing paper, epoxy, and other materials
required to assemble 200 singlemode connectors.
Note: Kits do not contain connectors, isopropyl alcohol, or nonozone-depleting canned air.
1.3 Epoxy Tool and Upgrade Kits
Kit Type (Note)
Kit Number
Comcode
Kit Includes
Epoxy Tool Kit
1032B5
106 705 213
110-volt curing oven
Epoxy Tool Kit
1032B6
106 919 012
220-volt curing oven
Note: In addition to the tool kit, the D-182959 Upgrade Kit (108 262 569) is also required.
Connectors
Crimp Sleeves
Removable
Duplex Yoke
Cable Supports
Regular
Duplex Yoke
Connector
Crimp Sleeve
Cable Support
Simplex Jumper Components*
Duplex Jumper Components
*Available one per package for simplex cord and two per package for SM duplex cord.