background image

3   |   OFS BRANDS

Electric Height Adjustable Tables

ASSEMBLY INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS

When using an electrical furnishing, basic precautions should always be followed, including 

the following:

This furnishing is made for commercial use only.

Read all instructions before using this furnishing:

DANGER

 – To reduce the risk of electrical shock:

1. 

Always unplug this furnishing from the electrical outlet before cleaning.

WARNING

 – To reduce the risk of burns, fire, electric shock, or injury to persons:

1. 

Unplug from outlet before putting on or taking off parts.

2.  Close supervision is necessary when this furnishing is used by, or near children, invalids, 

or disabled persons.

3.  Use the furnishing only for its intended use as described in these instructions. Do not 

use attachments not recommended by the manufacturer.

4.  Never operate this furnishing if it has a damaged cord or plug, if it is not working 

properly, if it has been dropped or damaged, or dropped in water. Return the furnishing 

to a service center for examination and repair.

5.  Keep the cord away from heated surfaces.
6.  Do not use outdoors.
7.  Use only SJT 18 AWG cord.
8.  Risk of injury. Maximum load 75 pounds.

To reduce the risk of electric shock, this furnishing has a polarized plug (one blade is wider 

than the other). This plug will fit in a polarized outlet only one way. If the plug does not fit 

fully in the outlet, reverse the plug. If it still does not fit, contact a qualified electrician to 

install the proper outlet. Do not change the plug in any way. 

Note – servicing is only to be performed by an authorized representative.

 

SERVICING OF DOUBLE-INSULATED PRODUCTS

 

In a double-insulated product, two systems of insulation are provided instead of grounding. 

No grounding means is provided on a double-insulated product, nor is a means for grounding 

to be added to the product. Servicing a double-insulated product requires extreme care and 

knowledge of the system, and is to be done only by qualified service personnel. Replacement 

parts for a double-insulated product must be identical to the parts they replace. A 

double-insulated product is marked with the words “DOUBLE INULATION” OR “DOUBLE 

INSULATED”. The symbol (square within a square) is also able to be marked on the product.

SAVE THESE INSTRUCTIONS

Содержание Electric Height Adjustable Tables

Страница 1: ...ASSEMBLY INSTRUCTIONS Electric Height Adjustable Tables ...

Страница 2: ...ustable Tables ASSEMBLY INSTRUCTIONS INSTRUCTIONS Required Tools Cordless Screwdriver 5mm Allen Wrench 1 2 Wrench HEIGHT ADJUSTABLE TABLE ASSEMBLY INSTRUCTIONS Rev Dwg Cordless Screwdriver 5mm Allen Wrench 1 2 Wrench Level 2 OFS BRANDS ...

Страница 3: ...d repair 5 Keep the cord away from heated surfaces 6 Do not use outdoors 7 Use only SJT 18 AWG cord 8 Risk of injury Maximum load 75 pounds To reduce the risk of electric shock this furnishing has a polarized plug one blade is wider than the other This plug will fit in a polarized outlet only one way If the plug does not fit fully in the outlet reverse the plug If it still does not fit contact a q...

Страница 4: ...angular column Use 4 M6 x 16MM flat head cap screws per column to attach mounting plate to top of column Place work surface bottom side up on a non marring surface Align holes on mounting plate with pre drilled holes on bottom side of work surface Fasten mounting hardware to worksurface using 8 12 X 1 truss head screws per column RECTANGULAR LEG SQUARE LEG SQUARE LEG RECTANGULAR LEG ELECTRIC ADJUS...

Страница 5: ...TER FOR CORNER UNIT AND 120 TABLES TURN TO PAGE 5 eries Part CENTER COLUMN Flat foot shown USER EDGE OFFSET COLUMN Flat foot shown USER EDGE 3 OFFSET COLUMN Long side of offset foot is towards the user edge TUBULAR FOOT Socket Head ELECTRIC ADJUSTABLE HEIGHT BASE ASSEMBLY RECTANGULAR OR SQUARE COLUMNS Button Head Align bolt holes in feet with threaded holes in the bottom of columns Feet are bored ...

Страница 6: ...n bottom side of work surface Use 2 8 x 2 pane head screws to secure to work surface To attach control panel determine if control panel is to be on the left or right side of the work surface Align control panel mount plate with pre drilled holes Use 2 X8 x 5 8 pan head screws to secure to work surface NOTE When attaching control box use the grooves on the upper face to help manage motor cables Rec...

Страница 7: ...rol box Secure cables using provided cord clips and velcro strips Figure A Series Part Rectangular or Square Columns RECTANGULAR TABLES 1 Snap together motor cable ends and leg cables Figure A 2 Plug the other end of the motor cable to the control box 3 Plug control panel cord into control box 4 Install anti collision dongle next to control panel cord Figure B Rectangular legs only 5 Last plug in ...

Страница 8: ...on bottom side of work surface Use 2 8 x 2 pane head screws to secure to work surface To attach control panel determine if control panel is to be on the left or right side of the work surface Align control panel mount plate with pre drilled holes Use 2 X8 x 5 8 pan head screws to secure to work surface NOTE When attaching control box use the grooves on the upper face to help manage motor cables Re...

Страница 9: ...ontrol box Secure cables using provided cord clips and velcro strips Figure A Series Part Rectangular or Square Columns CORNER UNIT 1200 TOPS 1 Snap together motor cable ends and leg cables Figure A 2 Plug the other end of the motor cable to the control box 3 Plug control panel cord into control box 4 Install anti collision dongle next to control panel cord Figure B Rectangular legs only 5 Last pl...

Страница 10: ...st be level from side to side and front to back Rev Dwg Rectangular or Square Columns 1 Table must be completely leveled before use 2 Adjust levelers by turning them in or out 3 Table must be level from side to side and front to back Electric Height Adjustable Tables ASSEMBLY INSTRUCTIONS 10 OFS BRANDS LEVEL LEVELER ...

Страница 11: ...he key until the desk stops completely 2 Reactivate the down key and hold the key until the desk stops completely Now the desk can drive up HOW TO STORE A MEMORY POSITION Favorite positions e g for sitting and or standing can be stored Follow the procedure shown in the text below How to store 1 Drive to the height you wish to store 2 Press S and then the Memory button The position has now been sto...

Страница 12: ...esk DPF1C 1 Measure the actual height of your desk from floor to the upper edge of the tabletop 2 Press the up and down keys at the same time 3 A figure appears in the display 4 Use the up or down key to change the figure to the actual height D THE DESK WILL NOT DRIVE THE FULL STROKE UPWARDS IT ALWAYS STOPS IN THE SAME POSITION The system has set a new end stop outwards To erase this position the ...

Страница 13: ...rksurface Rectangle with flat glide 28 47 625 Rectangle with flat caster 30 49 625 Rectangle with tubular glide 28 875 48 5 Rectangle with tubular caster 30 875 50 5 Square with flat glide 22 75 48 75 Square with flat caster 24 75 50 75 Square with tubular glide 23 75 49 75 Square with tubular caster 25 75 51 75 Glide Adjustment 1 4 Distributed Weight Capacity 75 lbs Volts 120v AC Frequency Phase ...

Страница 14: ...Electric Height Adjustable Tables ASSEMBLY INSTRUCTIONS PART 1750579 INSTRUCTION SHEET 2568INS 01 17 ...

Отзывы: