MPPT PRO-X 10A | 20A | 30A | 40A
— 18 —
5.
Parameters Setting
5.1.
Battery Parameters
5.1.1.
Supported battery types
1
Lead Battery
sealed (default)
gel
flooded
2
Lithium Battery
LiFePO4 (4S/8S/15S/16S)
Li (NiCoMn)O2 (3S/6S/7S/13S/14S)
3
Custom (USE)
Note:
If the controller supports 48V system voltage, the battery type will display LiFePO4 F15/F16
and Li (NiCoMn) O2 N13/N14.
5.1.2.
Local setting
WARNING
When the default battery type is selected, the battery voltage parameters cannot
be modified. To change these parameters, select the "USE" type.
Step1
:
Enter the “USER” battery type.
Detailed operations of entering the “USE” battery type are shown in the following table.
content
operation steps
enter the “USE”
battery type
1) Press the
button to browse the battery parameters on the initial
interface. Press the
button to enter the battery parameters setting
interface, and long-press the
button to enter the battery-type
interface.
2) Press the
or
button to select the battery type, such as select
the battery type as F04. And then press the
button to confirm.
Continue to press the
button twice or wait for 10S of no-operation to
automatically go back to the battery parameters setting interface.
3) Long-press the
button to enter the battery-type interface again on the
battery parameters setting interface.
4) Press the
or
button to select the battery type “USE.”