77
OETIKER EPC 01
TRoUblesHooTInG anD eRRoR MessaGes
Issue 11.22
08905306
Error message
Cause of the error
Troubleshooting measures
PE7014
When passing over the detection
gap, the measured force is less than
the pre-set detection force:
•
no clamp inserted
•
The clamp has already been
closed (attempted double clos-
ing)
•
The part being clamped is not
inserted
•
Detection gap set too large
•
Detection force set too high
Perform actions in the following sequence until the
error is eliminated:
►
Insert correct clamp and the parts being clamped.
►
Check the detection gap and reduce it if neces-
sary.
►
Check the detection force and reduce it if neces-
sary.
PE7015
The maximum speed of the pincer
has been exceeded:
•
The pincer jaws have slipped off
the clamp.
•
Clamp is broken.
•
Displacement measuring system
damaged
Perform actions in the following sequence until the
error is eliminated:
►
If the clamp is broken or the pincer jaws have
slipped, repeat closure using a new clamp.
►
send in the pincer and have it serviced.
PE7017
•
The Contact force could not
be reached before the Closing
force is reached.
►
Decrease the Contact force so it is lower than the
Closing force.
►
Insert correct clamp and the parts being clamped.
►
adjust closing gap tolerances so Contact force
and Closing force can be reached within the
tolerance field.
PE7018
•
During the force test the pincer
jaws were able to close com-
pletely. The force sensor was not
present.
►
Insert the force sensor
11 3 4 Description of the messages when measuring with the PC software
In the PC software, closures can be performed when the «Measure» function is activated. The messages de-
scribed in the table apply exclusively to this function. This information is required to supply the «Measure» screen
in the PC software with data. Measurement with the PC software is described in the
.
Message
Description
PM9000
Measuring is started
PM9010
The «Hold» function is used when measuring
PM9011
The «Detect» function is used when measuring
PM9020
The «Contact» function is used when measuring
PM9030
The «Close» function is used when measuring
PM9031
The «schnappi» function is used when measuring
PM9040
The «Verification» function is used when measuring
PM9050
The «sequence time» function is used when measuring