72
OETIKER EPC 01
TRoUblesHooTInG anD eRRoR MessaGes
Issue 11.22
08905306
11 3 2 Remedying errors of the «Handling» error type
Error message
Cause of the error
Troubleshooting measures
HE4001
Inlet pressure of the Control Unit
≤ 2.5 bar
►
Increase the inlet pressure of the Control Unit.
HE4002
no pincer detected:
►
Pincer is not connected
►
Pincer is defective
Perform actions in the following sequence until the
error is eliminated:
►
Check the connection of the pincer to the Control
Unit and connect it correctly if necessary.
►
send in defective pincer and have it repaired.
HE4003
no aPn selected:
•
aPn was not selected after
the device was started or after
sending a data set
•
no matching aPn available for
the pincer type
►
select an appropriate aPn.
►
Create and send aPn with corresponding
pincer type.
HE4004
Incorrect or non-existent closure/
process data and settings:
•
erroneous data received
•
error during firmware update
•
Memory is damaged
Perform actions in the following sequence until the
error is eliminated:
►
Check the data set and resend it if necessary.
►
Update the firmware (Customer admin).
►
send in the Control Unit and have it repaired.
HE4005
The crimping/measuring process
was aborted:
•
start button was released in jog
mode
•
Process aborted by external
device
•
Process abort at the Control
Unit or Trigger Unit by the op-
erator
•
errors in the control sequence
of the closure or the pincer test
•
selected holding force too low
•
selected open gap too small
•
selected verification force too
low
Perform actions in the following sequence until the
error is eliminated:
►
Check trigger mode setting and correct if neces-
sary.
►
Check the open gap parameter.
►
Check the hold parameter.
►
Check the verification parameter.
►
Check pincer jaws for blockage.
HE4006
Max. number of closures in force
test without force adjustment is
reached
►
Perform force adjustment. Proceed with the ad-
justment of the force or complete the pincer test
and crimp the clamps in closure mode.
HE4007
The set closure force cannot be
reached at the applied inlet pressure
►
Reduce the closure force. alternatively, increase
the inlet pressure.
HE4008
no pincer test performed:
•
The pincer has been newly
connected
•
Control Unit restarted
•
The calibration values were
overwritten when sending the
data set
►
Proceed with the pincer test.