42
OETIKER EPC 01
PC-sofTWaRe
Issue 11.22
08905306
8 5 3 Read data set
navigation:
Home > Control Unit > Read
on the
Read
menu page, data from the Control Unit are read into the PC software. either the data are read in as
a new data set or an existing data set is overwritten in the process. The reading in is done by pressing the
Read
button.
The log file of the Control Unit can also be read in (
). by selecting the
Include log data
function.
This is necessary, for example, in the event that support is being provided.
8 5 4 Sending the data set
navigation:
Home > Control Unit > Send
on the
Send
menu page, a newly created or edited data set is sent to the Control Unit.
The Control Unit determines specific values for each pincer test. When the
Overwrite calibration values
function
is performed, the defined values of the pincer test are overwritten with default values. The pincer must be recali-
brated after the data have been sent.
for minor editing operations (e.g. closure force or tolerances), sending the calibration values is optional.
Fig 23:
Read menu
Fig 24:
Send menu