OETIKER ELK 02 V2.X
8
Structure of the PC program
Issue 05.2021
08903352
8-65
System settings for pincer test
Fig. 43
System settings for pincer test
Input box/checkbox
Description
ELK02 - Power ON;
with mandatory pincer test “ZT”
Pincer test-mode, which asks for a mandatory pincer test when switching on the
ELK02 (default setting) (“ZT” = pincer test, see Table 27, page 9-74)
ELK02 - Power ON; with
function selection pincer test
“ZT” and “APN”*
Pincer test-mode, which allows to choose from two options when switching on
the ELK02:
•
pincer test
•
APN (“ZT” = pincer test, see Table 27, page 9-74)
ELK02 - Power ON; without
function selection, direct to
active “APN” *
Pincer test-mode, which directly opens the active APN when switching on the
ELK02
Pincer test prompt by external
bit pre-selection at X2
The pincer test is activated via the X2 interface.
Default: bit 10 (range bit 10-15)
Activation time: 500 ms (range 20 to 2000 ms).
Pincer test after number of
closures (counting from last
pincer test)
Range: 1 to 50,000; factory setting: 5000
If error message F18 QUANTITY is displayed,
•
The pre-set number has been reached
•
A pincer test is required