![OE Max Controls CSDP Plus Скачать руководство пользователя страница 126](http://html1.mh-extra.com/html/oe-max-controls/csdp-plus/csdp-plus_user-manual_3398524126.webp)
128
If a sudden excessive current flows through the
servo drive or the main circuit fails, this alarm will
occur.
Check the power supply and increase acceleration/
deceleration time.
If the over current flows through the servo drive or
the main circuit fails, this alarm will occur.
Check the power supply and increase acceleration/
deceleration time.
If the ambient temperature is 55
°
C or higher, IPM
unit failed, or the power supply is low voltage, this
alarm can occur.
Check the power supply and lower the ambient
temperature.
If the torque feedback continues with the
maximum torque for several seconds, this alarm
can occur.
Check the load condition, power supply and motor
capacity, and increase acceleration /deceleration
time.
If 115% or more torque feedback continues for
several seconds, this alarm can occur.
Check the load condition, power supply and motor
capacity, and increase acceleration /deceleration
time.
If the temperature of heatsink plate of servo drive
is over about 95
±
10
°
C, this alarm will occur.
Check the power supply and lower the ambient
temperature.
If the power cable of the motor is not connected,
this alarm will occur.
Connect the motor power cable to the motor and
the servo drive properly.
If drive capacity is exceeded, this alarm will occur .
Check the load condition of the power supply.
If the servo drive is overloaded, this alarm will
occur.
Check the load condition of the servo drive.
Содержание CSDP Plus
Страница 1: ...Maximum Value for OEMs SM CSDP Plus Servo Drive User Manual...
Страница 16: ...18...
Страница 21: ...23 The sizes of CSDP 15BX2 CSDP 20BX2 CSDP 30BX2 are as below The sizes of CSDP 40BX2 CSDP 50BX2 are as below...
Страница 30: ...32 Higher Control Connector CN1 Circuit Diagram...
Страница 33: ...35 Compact Absolute Encoder Wiring Serial Encoder Wiring...
Страница 36: ...38 Grounding Wiring Please separate the input and output wires of the filter and do not tie them together...
Страница 38: ...40...
Страница 120: ...122...
Страница 179: ...181 Speed Torque Curve...
Страница 180: ...182...
Страница 183: ...185 Speed Torque Curve...
Страница 184: ...186...
Страница 187: ...189...
Страница 190: ...192 Speed Torque Curve...
Страница 193: ...195...
Страница 196: ...198...
Страница 201: ...203...
Страница 204: ...206...
Страница 207: ...209...
Страница 210: ...212...
Страница 215: ...217...
Страница 230: ...232...
Страница 252: ...254...