2. Open the TCP Debugging Assistant test tool, select TCP Server, set the remote host
IP address to 192.168.1.254, local port no: 6001, and click Start monitoring.
Страница 1: ...http www odotautomation com 1 29 TEL 86 0816 2538289 Protocol Converter ODOT S1E1V2 0 User Manual V2 00 2020 03 16...
Страница 2: ...http www odotautomation com 2 29 TEL 86 0816 2538289 ODOT Series ODOT S1E1V2 0 ODOT Automation System Co Ltd 2022 03 Copyright 2012 ODOT Automation all rights reserved...
Страница 3: ...ment shall not be republished as a paper or electronic document Disclaimer This document is only intended to assist the reader in using the products and the company shall not be responsible for any lo...
Страница 4: ...9 2 4 Reset switch 9 2 5 External terminal resistance 11 2 6 Installation dimension 12 3 Typical application 12 3 1 Transparent transmission with protocol data 12 3 1 1 TCP_SERVER pattern 13 3 1 2 TCP...
Страница 5: ...nput anti reverse connection protection DC DC isolation power supply 3000V isolation voltage 2KV network port isolation protection 10M 100Mbps rate adaptive automatic MDI MDIX reversal Support TCP ser...
Страница 6: ...er ports 1 Input voltage 9 36V DC Power consumption 700mW Ethernet parameters Working mode TCP server TCP client UDP Number of Ethernet ports 1 Network protocol TCP UDP HTTP Number of TCP connections...
Страница 7: ...http www odotautomation com 7 29 TEL 86 0816 2538289 2 Hardware description 2 1 Product appearance...
Страница 8: ...ol Definition State Instruction PWR Power LED ON Power supply is connected OFF Power supply is not connected STA Converter status LED Flash The converter is running properly OFF The converter is not r...
Страница 9: ...ick the reset button and all the indicators blink once to indicate a successful reset Gateway reset successfully the technical parameters of the gateway are as follows serial numbe r Terminal RS485 RS...
Страница 10: ...Configuration Baud rate 1200 115200 default 115200 Data bit 5 6 7 8 default 8 Parity bit None odd check even check default None Stop bit 1 2 default 1 Flow Control None Advance Level None data restar...
Страница 11: ...the resistance value is required to be approximately equal to the transmission cable characteristic impedance In short distance transmission no final resistance is required that is no final resistance...
Страница 12: ...s transparent transmission with and without protocol The S1E1 supports browser configuration and it directly forwarding data without storing 3 1 Transparent transmission with protocol data Example ODO...
Страница 13: ...cking No check odd check even check can be selected default no check please set this parameter to the serial port Stop bits 1 t 2 bit stop is optional default is 1 bit stop Set this parameter to match...
Страница 14: ...ld not be logged in or the config page is displayed abnormally pls disable the wireless network card and log in again If the login IP address is forgotten it could press the reset key to restore the f...
Страница 15: ...e port 502 Wok mode TCP client set the Destination IP DNS to the server IP address to be connected 192 168 1 51 IP address of the local NIC and remote port number 6001 Serial port device parameters 19...
Страница 16: ...www odotautomation com 16 29 TEL 86 0816 2538289 2 Open the TCP Debugging Assistant test tool select TCP Server set the remote host IP address to 192 168 1 254 local port no 6001 and click Start monit...
Страница 17: ...rrect serial port number and communication parameters in the pop up window and click OK After the Settings MODBUS master message is sent in the TCP debugging Assistant sending window and Automatic Sen...
Страница 18: ...ion reads one message segment at a time from the queue 1 Open Google browser and enter 192 168 1 254 to log in to the webpage configuration interface Network config IP address 192 168 1 254 device por...
Страница 19: ...ugh computer serial port USB to 485 converter Open TCP Debugging Assistant select UDP and set the remote host IP address 192 168 1 254 remote port 502 and local port 6000 Click to enable UDP Open Modb...
Страница 20: ...g Assistant sending window and Automatic Sending is selected to collect MODBUS Slave data 3 2 None protocol data transmission 3 2 1 TCP_SERVER pattern 1 Open Google browser and enter 192 168 1 254 to...
Страница 21: ...Serial Port devices Multiple Host Config Select the conversion protocol as none Click Submit when the Settings are completed Open the TCP debug assistant simulate the TCP Client and access the convert...
Страница 22: ...ort number 6004 Serial port device parameters 19200bps N81 The Serial Port test tool Serial Port Utility is used to simulate Serial Port devices Multiple Host Config Select the conversion protocol as...
Страница 23: ...evice port 502 work mode UDP mode set the Destination IP DNS to the server IP address to be connected 192 168 1 51 IP address of the local NIC and remote port number 6005 Serial port config serial por...
Страница 24: ...16 2538289 Open the TCP debugging assistant to simulate the UDP connection protocol converter Open the Serial Port Utility to simulate the underlying Serial Port device The following figure shows the...
Страница 25: ...transmission distance is less than 4 under the condition of standard values of 50 feet 15 meters more than 15 m long distance communication need to adopt modem the maximum transmission distance is als...
Страница 26: ...acteristics it can only realize point to point communication RS232 communication wiring diagram is shown in the figure below 2 RS422 The full name of RS422 interface standard is Electrical Characteris...
Страница 27: ...very short distances Generally the maximum transmission rate obtained on 100 meters long twisted pair is only 1Mb s The RS 422 requires a terminal resistance that is approximately equal to the charac...
Страница 28: ...ence resistance Because the semi duplex network composed of RS485 interface generally adopts the wiring mode of two wire system and adopts differential signal to transmit data the voltage difference b...
Страница 29: ...stance is generally required below 300 meters The final resistance is connected at the ends of the transmission cable RS485 9 pin definition Pin Name Function Remark 1 Data B 485 Send positive Must co...