1. Ventilation Slit
The air from the front and sides of the unit are taken in and exhausted from the rear.
2. 16char-Type LCD Display
Voltage/Current value, settings, and various menus are displayed here.
3. CV Mode Lamp
Turned on when the unit is currently in CV (Constant Voltage) Mode.
4. CC Mode Lamp
Turned on when the unit is currently in CC (Constant Current) Mode.
5. Limit Display Lamp
LED is lit when the voltage/current is being set.
LED is turned off if the current voltage/current output is displayed.
6. Remote Interface Lamp
LED is turned on when the remote interface is active.
In this case, the front panel cannot be used.
7. Key Lock Lamp
The front panel is locked and cannot be used if this lamp is on.
8. Error Lamp
LED is lit when various errors occur and turned off when all errors have been confirmed.
9. Voltage Settings Encoder
Used for adjusting the voltage limit settings or values in the menu.
10. Current Settings Encoder
Used for adjusting the current limit settings or values in the menu.
11. Voltage Cursor or Menu Change Key
Cursor key exclusive for voltage. The cursor moves left for each press of the button,
and it is used to move the menu.
12. Current Cursor or Menu Change Key
Cursor key exclusive for current. The cursor moves right for each press of the button,
and it is used to move the menu.
13. Output Voltage/Current ON/OFF
Used for disabling the output voltage/current.
- 13 -
Содержание MX Series