SERVICE TIP

TROUBLESHOOTING STRIDE ERRORS

If the LX8000T stride is not adjusting properly and you do not feel or hear the stride motors working, perform the following steps: 

mast boot

hood

screws

MARCH 2015

SUPPORT.OCTANEFITNESS.COM

Run diagnostics by tapping the Octane logo “

O

” “

E

” “

E

” “

O

” on the main screen, use Password 

922

 and then press 

Enter

.

If Right or Left Stride Errors are present, clear the errors by pressing 

Reset

 and then 

Exit

.

Inspect stride motor connections by disconnecting the power supply, removing the mast boot and hood, disconnecting the battery 
and then disconnecting/reconnecting the stride motor connections.

Reconnect the battery and the power supply, and then test the machine: you should hear and feel the stride motors adjusting. If stride 
motors are working, reattach the hood and mast boot and you’re done.

 If stride motors still are not working, continue on with step