INPUT

OUTPUT

INPUT

CO2

INSTALLATION

Place the OCL DLC 1.1 digital lighting controller outside the climate room, connect the included power adaptor to POWER. To correctly 
measure the CO2 level, place the CO2 sensor in the climate room. Together, the Controller, Power supply and the Sensor regulate the  
CO2 generator or bottle. Certain conditions need to be met to ensure  correct operation of the CO2 sensor.

The CO2 sensor needs to be in the direct vicinity of the CO2 source and should 
be placed within at least  50cm of the source. Place the sensor about 1 meter 
above the floor. It is  recommended not to place the CO2 sensor above the 
CO2 generator or bottle, or in the direct airflow of fans, as this will influence the 
measurements. 

PLEASE MAKE SURE THAT THE CO2 SENSOR IS IN THE LIGHT:

The sensor needs to detect light, in order to be able to correctly measure the 
CO2 level in the climate room. The light cell  itself is not visible but is behind the 
grooves of the sensor casing. Insert [1] the plug of the CO2 generator or the CO2 
pressure reducing valve into the “POWER SUPPLY” [2]. The green LED [3] 
indicator lights up when a CO2 dosage is given.

The UTP-cable is plugged into the OCL DLC1.1 port of the lighting controller 
marked “CO2”. Subsequently plug the UTP-cable supplied in the “INPUT” port 
of the power supply with led indicator. Then plug the other CO2-cable supplied 
in the “OUTPUT” of the power supply with led indicator thereby connecting the 
CO2-sensor.

The CO2-generator or the pressure reducing valve can now be connected to 
the “POWER SUPPLY” with led indicator.

50 

CM

100 

CM

CO

2

 SENSOR WITH LIGHT CELL

2

3

1