5.3
Operation selection heating circuit
The following modes of operation can be set:
Mode of operation
Description
0: Standby mode
Heating circuit OFF (frost protection function still active)
1: Automatic
Automatic control according to the time program set, auto-
matic switch-over HEATING/COOLING
(recommended)
4: Normal heating
mode
Without timer program, the heater control always controls to
room temperature set value.
5: Economy heating
mode
Without timer program, the heater control always controls to
set-back room temperature set value.
7: Manual heating
mode
Heating to a permanent set flow value (07-009)
Heating curve not active
8: Manual cooling mode Heating to a permanent set flow value (07-009)
Heating curve not active
Settings procedure:
1.
Press
the adjustment button in the main
display > the main menu appears
2.
Select the Heating Circuit by
turning
the ad-
justment knob and confirm by
pressing
the
knob.
3.
In heating circuit temperature image, select
the sub-menu by
pressing
the adjustment
knob.
4.
Confirm the
operation mode
by
pressing
the
adjustment knob
5.
Confirm the
operation mode
by
pressing
the
adjustment knob
6.
Set the operation mode by
turning
the ad-
justment knob and store this by
pressing
.
HEATING CIRCUIT 1
ESC
MENU
03-050
Operation mode selection
heating
1: Automatic
HEATING CIRCUIT 1
ESC
ENTER
ESC
ENTER
1
07-009
Setpoint temper 30.0
HEATING CIRCUIT 1
03-050
Operation mode
HEATING CIRCUIT 1
Operation mode
Operational data
Settings
Relay test
ESC
ENTER
HEATING CIRCUIT 1
HEATING CIRCUIT 2
HOT WATER
HEAT PUMP
ESC
ENTER
Main menu
Heating m ode
OCHSNER OTE
MENU
Sa 05.08.2017
08:10
1
2
3
4
5
6