BA_OLW I OTE3_SW5x_EN_20160815_V2
23 / 48
of the appliance or on the air con-
duits.
not finished.
should not occur again if sufficient
venting or dehumidification of the
room is carried out ca. two years
after the house is built.
A relatively high humidity (
≥60 %).exists Condensate on the appliance
should not re-occur when weather
conditions change.
The appliance installed is in a damp-
room. Damp rooms are those in which
high air humidity occurs, for instance
due to clothes drying.
Make sure the room is sufficiently
ventilated and dehumidified. If
possible, hang your washing in
another room.
Use an exhaust air dryer. Note that
circulation driers do not lead to a
reduction in the air humidity.
The air hoses are not correctly installed
Cold air exits the appliance.
Check whether the air hoses are
correctly installed and sealed. Call
your specialist installer if neces-
sary.
Table 2: Trouble shooting
13.1 Error Codes OTE3 for Airstation
Code
No. Logfile
Error description
Possible cause/ remedy
115
Er 01: Hot water sensor defect
Replace sensor
116
Er 10: Outside sensor defect
Replace sensor
117
Er 14: Mixer sensor defect
Replace sensor
124
Er 20: TWR sensor defect
Replace sensor
120
Er 22: Switch-off sensors TWR/TPM de-
fect
Replace sensor
136
Er 23: TPV sensor defect
Replace sensor
118
Er 24: Buffer sensor defect
Replace sensor
114
Er 29: TWV sensor defect
Replace sensor
8
8
Er 42: Frost protection in heating system
Insufficient heat distribution, circulation pump
defect, valve closed / air in the system,
check the buffer pump or the hydraulics
143
143
Er 59: Sensor breakage TWV + TWR
Check sensor
42
42
Er 71: Bus malfunction, room remote
control
Check eBus wiring
30
30
Er 80: Address WEZ 1
Check addressing
31
31
Er 81: Address WEZ 2
Check addressing
32
32
Er 82: Address WEZ 3
Check addressing
33
33
Er 83: Address WEZ 4
Check addressing
34
34
Er 84: Address WEZ 5
Check addressing
35
35
Er 85: Address WEZ 6
Check addressing
36
36
Er 86: Address WEZ 7
Check addressing
37
37
Er 87: Address WEZ 8
Check addressing
20
20
Er 91: Flow rate heating system
Water pressure too low, circulation pump defect,
valve closed/air in system, check hydraulics
104
104
Er104: Buzzer malfunction heat pump
ELW and Airstation - Ochsner Customer Service
Table 3: OTE3 Error codes for OLWI
Содержание OLWI 9
Страница 2: ...BA_OLW I OTE3_SW5x_EN_20160815_V2 2 48...
Страница 25: ...BA_OLW I OTE3_SW5x_EN_20160815_V2 25 48 14 2 Hydraulic diagram...
Страница 26: ...BA_OLW I OTE3_SW5x_EN_20160815_V2 26 48 14 3 Electric circuit diagrams OTE...
Страница 27: ...BA_OLW I OTE3_SW5x_EN_20160815_V2 27 48...
Страница 28: ...BA_OLW I OTE3_SW5x_EN_20160815_V2 28 48...
Страница 29: ...BA_OLW I OTE3_SW5x_EN_20160815_V2 29 48 14 4 Wiring overview...
Страница 37: ...BA_OLW A I OTE3_SW5x_DE_20160510_V2 37 48 15 Declaration of Conformity...
Страница 38: ...BA_OLW I OTE3_SW5x_EN_20160815_V2 38 48...
Страница 39: ...BA_OLW A I OTE3_SW5x_DE_20160510_V2 39 48 16 ERP Data...
Страница 40: ...BA_OLW I OTE3_SW5x_EN_20160815_V2 40 48...
Страница 47: ...BA_OLW I OTE3_SW5x_EN_20160815_V2 47 48...