OTS_EN | www.ochsner.com 39
Bivalent point
Description
Unit
Switching cycles
today
The switching cycles for the current day
are displayed here.
-
14.3.2
Buffer tank electric auxiliary heater
Description
Unit
Operating status:
buffer tank auxil-
iary heater
The status of the auxiliary heater is dis-
played here.
-
Heating
The electric auxiliary heater is in heating
mode.
Standby
There is no heat demand.
Outdoor
temperature
shutdown
The heat demand is blocked by the out-
door temperature.
Fault
There is a fault.
Operating
program
switched off
The electric auxiliary heater is switched
off by selecting the following operating
program: “Off”
Starting pro-
cedure
Operation of the electric auxiliary heater
starts.
Shutdown
procedure
Operation of the electric auxiliary heater
ends.
Switching cycles:
buffer tank auxil-
iary heater
Absolute switching cycles are displayed
here.
-
Switching cycles:
buffer tank auxil-
iary heater today
The switching cycles for the current day
are displayed here.
-
14.3.3 DHW tank electric auxiliary heater
Description
Unit
Operating status:
DHW tank auxilia-
ry heater
The status of the auxiliary heater is dis-
played here.
-
Heating
The electric auxiliary heater is in heating
mode.
Standby
There is no heat demand.
Outdoor
temperature
shutdown
The heat demand is blocked by the out-
door temperature.
Fault
There is a fault.
Operating
program
switched off
The electric auxiliary heater is switched
off by selecting the following operating
program: “Off”
Starting pro-
cedure
Operation of the electric auxiliary heater
starts.
Shutdown
procedure
Operation of the electric auxiliary heater
ends.
Switching cycles:
DHW tank auxilia-
ry heater
Absolute switching cycles are displayed
here.
-
Switching cycles:
DHW tank auxilia-
ry heater today
The switching cycles for the current day
are displayed here.
-
14.3.4 Viewing operating data
»
Open the menu.
»
Select “Auxiliary heater”.
»
Select “Operating data”.
15. Bivalent point
Parameters
Description
Unit
Bivalent point
The outdoor temperature from which
part of the heat load is taken over by the
auxiliary heater, is set here. It should not
be switched on until the output that is
demanded is greater than the heat pump
can provide, due to the low outdoor tem-
perature.
°C
X Outdoor air temperature [°C]
Y Heating output [kW]
1 Standard outdoor temperature
2 Bivalent point
3 Heating limit
4 Electric auxiliary heater share
5 Surplus energy
6 Max. heat pump heating output
7 Required heating output at standard outdoor
temperature
8 Min. heat pump heating output
9 Modulation range
Note
If the bivalent point is set too high, there may be
higher running costs due to the auxiliary heater
being switched on too early.
If the bivalent point is set too low, the heat pump
may not reach the required temperatures for DHW
and heating.
»
Only make changes to this parameter in con-
sultation with your system partner.
Содержание AIR FALCON 212
Страница 7: ...BA 982018 AIR FALCON sh EN www ochsner com 7...
Страница 9: ...00_400_200_202_01_split_Funktionsweise EN www ochsner com 9 How split systems work...
Страница 65: ...OTS_EN www ochsner com 65 Expert mode...
Страница 77: ...OTS_ZSM_EN www ochsner com 77...
Страница 85: ...BA 982018 AIR FALCON EN07 www ochsner com 85...
Страница 86: ...Notes...
Страница 87: ...Notes...