38
www.ochsner.com | OTS_EN
Electric auxiliary heater
14. Electric auxiliary heater
Note
The activity of the electric auxiliary heater has the
option to be shown on the heat pump display.
»
Inform OCHSNER Customer Service during
commissioning if you require this optional ver-
sion (CH).
14.1 Position of the auxiliary heater
The electric auxiliary heater can be installed at various
points in the heating system, depending on the heat pump
and heating system. Subject to the position, only the pa-
rameters applicable to your system are displayed on the
controller.
The following electric auxiliary heaters are possible:
Parameters
Position
Electric auxiliary heater internal
Heat pump
Buffer tank electric auxiliary
heater
Buffer tank
DHW tank electric auxiliary
heater
DHW tank
14.2 Operating program
Operating program
Description
Off
The auxiliary heater is switched off. Frost
protection remains active.
Automatic
The auxiliary heater operates in automatic
mode. Depending on the heat demand,
it will be switched on and off automati-
cally. The auxiliary heater is not normally
switched on until the bivalent point is un-
dershot.
In exceptional cases the auxiliary heater
may also switch on irrespective of the bi-
valent point:
The auxiliary heater switches on if the heat
pump is not enabled as the heat generator.
This can happen if there is a fault or the
limits of use have been exceeded.
The auxiliary heater switches on if more
output is required than the heat pump can
provide. This can happen if the heat pump
is already close to reaching the limits of
use.
14.2.1 Setting the operating program
»
Open the menu.
»
Select “Auxiliary heater”.
»
Select “Operating program”.
»
Select the preferred operating program.
»
Make the required settings.
»
Return to the main screen.
14.3 Operating data
14.3.1 Electric auxiliary heater internal
Description
Unit
Operating status:
internal auxiliary
heater
The status of the auxiliary heater is dis-
played here.
-
Heating
The auxiliary heater is in heating mode.
Standby
There is no heat or DHW demand.
DHW
The auxiliary heater is in DHW mode.
Outdoor
temperature
shutdown
The heat demand is blocked by the out-
door temperature.
Fault
There is a fault.
Frost protec-
tion mode
The auxiliary heater is in frost protection
mode.
Maximum
temperature
shutdown
The auxiliary heater is switched off be-
cause the flow temperature is too high.
Electricity tar-
iff shutdown
An electricity tariff shutdown of the heat
pump has taken place.
Operating
program
switched off
The auxiliary heater is switched off by
selecting the following operating pro-
gram: “Off”
Starting pro-
cedure
Operation of the auxiliary heater starts.
Shutdown
procedure
Operation of the auxiliary heater ends.
Minimum sys-
tem pressure
The system pressure fell below the
permissible minimum. If the system
pressure is too low, operability may be
restricted. Control the system pres-
sure and top up the heating water that
complies with the relevant standards if
required.
Output stage 1
The output of the internal electric aux-
iliary heater is controlled in 3 stages.
These are controlled via a binary signal
displayed here.
This parameter is only displayed if an
internal electric auxiliary heater is avail-
able.
-
Output stage 2
Stage 1
Output stage 1
= ON
Output stage 2
= OFF
Stage 2
Output stage 1
= OFF
Output stage 2
= ON
Full out-
put
Output stage 1
= ON
Output stage 2
= ON
Heat pump flow
temperature
The flow temperature is displayed here.
If an internal electric auxiliary heater is
installed, the flow temperature upstream
of the auxiliary heater is displayed here.
°C
Flow temperature
auxiliary heater
The flow temperature, downstream of
the integrated electric auxiliary heater, is
displayed here.
This parameter is only displayed if an
internal electric auxiliary heater is avail-
able.
°C
Switching cycles
Absolute switching cycles are displayed
here.
-
Содержание AIR FALCON 212
Страница 7: ...BA 982018 AIR FALCON sh EN www ochsner com 7...
Страница 9: ...00_400_200_202_01_split_Funktionsweise EN www ochsner com 9 How split systems work...
Страница 65: ...OTS_EN www ochsner com 65 Expert mode...
Страница 77: ...OTS_ZSM_EN www ochsner com 77...
Страница 85: ...BA 982018 AIR FALCON EN07 www ochsner com 85...
Страница 86: ...Notes...
Страница 87: ...Notes...