DHW circuit
►
COMFORT
►
BOOST
The active operating program is displayed in with red.
1 ECO mode
2 COMFORT mode
3 BOOST mode
12.3
Target values and switching differentials
Different target values and switching differentials can be
set for the different operating programs.
A distinction is
made between the standard target value and the reduced
target value.
ECO
Parameters
Description
Unit
DHW temper-
ature:
Target value
for Eco
The time program is used to switch be-
tween the following target values:
°C
Target value for Eco
Target value for Reduced
Switch-ON
differential:
Eco
Heating is enabled under the following
conditions:
K
The temperature is regulated to the target
value: Target value for Eco
The DHW temperature falls below the tar-
get value by the value set here.
Parameters
Description
Unit
DHW temper-
ature:
Target value
for Reduced
The time program is used to switch be-
tween the following target values:
°C
Target value for Eco
Target value for Reduced
Switch-ON
differential:
Reduced
Heating is enabled under the following
conditions:
K
The temperature is regulated to the target
value: Target value for Reduced
The DHW temperature falls below the tar-
get value by the value set here.
COMFORT
Parameters
Description
Unit
DHW temper-
ature:
Target value
for Comfort
The time program is used to switch be-
tween the following target values:
°C
Target value for Comfort
Target value for Reduced
Switch-ON
differential:
Comfort
Heating is enabled under the following
conditions:
K
The temperature is regulated to the target
value: Target value for Comfort
The DHW temperature falls below the tar-
get value by the value set here.
DHW temper-
ature:
Target value
for Reduced
The time program is used to switch be-
tween the following target values:
°C
Target value for Comfort
Target value for Reduced
Switch-ON
differential:
Reduced
Heating is enabled under the following
conditions:
K
The temperature is regulated to the target
value: Target value for Reduced
The DHW temperature falls below the tar-
get value by the value set here.
BOOST
Parameters
Description
Unit
DHW temper-
ature:
Target value
for Boost
The temperature is regulated to the target
value set here.
°C
12.3.1
Setting target values and switching differentials
The target values can be changed directly from the main
screen of the relevant DHW circuit or via the menu. (See
page 30, Setting the DHW temperature)
The switching differentials can be changed via the menu.
»
Open the menu.
Содержание AIR FALCON 212
Страница 7: ...BA 982018 AIR FALCON sh EN www ochsner com 7...
Страница 9: ...00_400_200_202_01_split_Funktionsweise EN www ochsner com 9 How split systems work...
Страница 65: ...OTS_EN www ochsner com 65 Expert mode...
Страница 77: ...OTS_ZSM_EN www ochsner com 77...
Страница 85: ...BA 982018 AIR FALCON EN07 www ochsner com 85...
Страница 86: ...Notes...
Страница 87: ...Notes...