INSTALLATION | Specification
50
www.ochsner.com | 982000-AIR-M2-M4-EN03.1
14.
Specification
14.1 Heat pumps for three-phase alternating
current
14.1.1 Data table
AIR 7 C11A
AIR 11 C11A
AIR 18 C11A
INDOOR UNIT:
Hydraulic variant
M2-1/M2-2/M2-3/M2-4 M2-1/M2-2/M2-3/M2-4 M2-1/M2-2/M2-3/M2-4
Dimensions HxWxD
[mm]
1286x600x680
1286x600x680
1286x600x680
Hydraulic connection
DN 32 (1 1/4”) male
DN 32 (1 1/4”) male
DN 32 (1 1/4”) male
Weight
[kg]
114
124
135
Casing colour
Tiger white 29/11289/
grey RAL 7016
Tiger white 29/11289/
grey RAL 7016
Tiger white 29/11289/
grey RAL 7016
HEATING MODE PERFORMANCE DATA:
Standard point L10/W35
Heating output
[kW]
6.8
11
16
Total power consumption / operating current
[kW]/[A]
1.33 / 2.65
2.3 / 4.7
3 / 6.2
Coefficient of performance EN 14511/EN 255
5.1 / 5.6
4.9 / 5.2
5.3 / 5.6
Operating point L7/W35
Heating output
[kW]
6.4
10.2
15.1
Total power consumption / operating current
[kW]/[A]
1.33 / 2.65
2.3 / 4.5
3 / 6.2
Coefficient of performance EN 14511/EN 255
4.8 / 5.3
4.5 / 4.7
5 / 5.3
Standard point A2/W35
Heating output
[kW]
5.4
8.8
13.2
Total power consumption / operating current
[kW]/[A]
1.32 / 2.64
2.2 / 4.4
3 / 6.2
Coefficient of performance EN 14511/EN 255
4.1 / 4.5
4 / 4.3
4.4 / 4.7
Standard point L-7/W35
Heating output
[kW]
4.1
6.8
10.6
Total power consumption / operating current
[kW]/[A]
1.28 / 2.6
2 / 4.2
3 / 6.1
Coefficient of performance EN 14511/EN 255
3.2 / 3.5
3.3 / 3.6
3.6 / 3.8
Operating point L-10/W35
Heating output
[kW]
3.7
6.2
9.9
Total power consumption / operating current
[kW]/[A]
1.25 / 2.55
2 / 4.1
2.9 / 6
Coefficient of performance EN 14511/EN 255
3 / 3.3
3.1 / 3.3
3.4 / 3.6
Operating point A2/W50
Heating output
kW
4.7
7.9
12.3
Total power consumption / operating current
[kW]/[A]
1.75 / 3.4
2.8 / 5.8
4 / 8.2
Coefficient of performance EN 14511/EN 255
2.7 / 2.9
2.8 / 3
3.1 / 3.2
Operating point A2/W60
Heating output
[kW]
4.3
7.6
12.1
Total power consumption / operating current
[kW]/[A]
1.95 / 3.6
3.2 / 6.6
4.4 / 9.1
Coefficient of performance EN 14511/EN 255
2.2 / 2.4
2.4 / 2.5
2.8 / 2.9
COOLING MODE PERFORMANCE DATA:
Operating point A30/W18
Cooling capacity
[kW]
4.4
9.6
11.2
Total power consumption / operating current
[kW]/[A]
1.34 / 2.8
3 / 6.2
3.3 / 6.8
Energy efficiency ratio EER
3.3
3.2
3.4
Operating point A30/W7
Cooling capacity
[kW]
3.1
8.7
10.7
Total power consumption / operating current
[kW]/[A]
1.39 / 2.9
2.9 / 6
3.3 / 6.8
Energy efficiency ratio EER
2.2
3
3.2
SPECIFICATION:
Phases/nominal voltage/frequency
[~]/[V]/[Hz]
3/400/50
3/400/50
3/400/50
Output factor cos ϕ
0.7
0.7
0.76
Fuse
C10A
C10A
C16A
Max. operating current
[A]
5.4
7.9
11.4