ADJUSTMENTS AND
MAINTENANCE
UT-MT-0812_2.0_24-01-2023 (EN)
Use and Maintenance Manual
LERA
48
4.9
Replacement of the arctic kit
4.9.1 Replacement of the resistance
Before carrying out any intervention on the device, cut off all external power sources and
place appropriate work-in-progress warnings on the systems.
Wait for the discharging time (at least 5 minutes) and check using appropriate instruments
that there are no residual energies before accessing the electrical equipment.
Unscrew the four screws and remove the front frame complete with lower gasket and glass. Disconnect the supply
cables of the resistance.
Remove the film and glue the new resistance on the new glass, taking care to position it correctly so that it does
not come out of the edge