EXPLORE
E7
2020 INSTALL & OPERATION MANUAL
29
7.4 CABLE GAUGE CHART 12V
Supply & Return Cable Conductor Size Chart 3% drop for when using 12V DC supply
Cable
length
(feet)*
Circuit Current
2 Amp
4 Amp
6 Amp
8 Amp
10 Amp
15 Amp
20 Amp
25 Amp
30 Amp
40 Amp
50 Amps
0-5
18 AWG
18 AWG
16 AWG
16 AWG
14 AWG
12 AWG
12 AWG
10 AWG
10 AWG
8 AWG
8 AWG
5-10
18 AWG
16 AWG
14 AWG
12 AWG
12 AWG
10 AWG
8 AWG
8 AWG
6 AWG
6 AWG
4 AWG
10-15
16 AWG
14 AWG
12 AWG
10 AWG
10 AWG
8 AWG
6 AWG
6 AWG
4 AWG
4 AWG
2 AWG
15-20
16 AWG
12 AWG
10 AWG
10 AWG
8 AWG
6 AWG
6 AWG
4 AWG
4 AWG
2 AWG
2 AWG
20-25
14 AWG
12 AWG
10 AWG
8 AWG
8 AWG
6 AWG
4 AWG
4 AWG
2 AWG
2 AWG
1 AWG
25-30
14 AWG
10 AWG
10 AWG
8 AWG
6 AWG
4 AWG
4 AWG
2 AWG
2 AWG
1 AWG
0 AWG
30-35
14 AWG
10 AWG
8 AWG
8 AWG
6 AWG
4 AWG
4 AWG
2 AWG
2 AWG
1 AWG
0 AWG
35-40
12 AWG
10 AWG
8 AWG
6 AWG
6 AWG
4 AWG
2 AWG
2 AWG
1 AWG
0 AWG
0/2
AWG
40-45
12 AWG
10 AWG
8 AWG
6 AWG
4 AWG
4 AWG
2 AWG
2 AWG
1 AWG
0 AWG
0/2
AWG
45-50
12 AWG
8 AWG
6 AWG
6 AWG
4 AWG
2 AWG
2 AWG
1 AWG
0 AWG
0/2
AWG
0/3
AWG
50-55
12 AWG
8 AWG
6 AWG
6 AWG
4 AWG
2 AWG
2 AWG
1 AWG
0 AWG
0/2
AWG
0/3
AWG
55-60
10 AWG
8 AWG
6 AWG
4 AWG
4 AWG
2 AWG
1 AWG
0 AWG
0 AWG
0/3
AWG
0/4
AWG
60-65
10 AWG
8 AWG
6 AWG
4 AWG
4 AWG
2 AWG
1 AWG
0 AWG
0/2
AWG
0/3
AWG
0/4
AWG
65-70
10 AWG
8 AWG
6 AWG
4 AWG
4 AWG
2 AWG
1 AWG
0 AWG
0/2
AWG
0/3
AWG
0/4
AWG
70-75
10 AWG
6 AWG
4 AWG
4 AWG
2 AWG
2 AWG
0 AWG
0/2
AWG
0/2
AWG
0/4
AWG
75-80
10 AWG
6 AWG
4 AWG
4 AWG
2 AWG
1 AWG
0 AWG
0/2
AWG
0/3
AWG
0/4
AWG
80-85
10 AWG
6 AWG
4 AWG
4 AWG
2 AWG
1 AWG
0 AWG
0/2
AWG
0/3
AWG
0/4
AWG
85-90
10 AWG
6 AWG
4 AWG
4 AWG
2 AWG
1 AWG
0 AWG
0/2
AWG
0/3
AWG
0/4
AWG
90-95
8 AWG
6 AWG
4 AWG
2 AWG
2 AWG
1 AWG
0/2
AWG
0/3
AWG
0/3
AWG
95-100
8 AWG
6 AWG
4 AWG
2 AWG
2 AWG
0 AWG
0/2
AWG
0/3
AWG
0/4
AWG
*One-way cable length from supply (usually battery) to load.