Unless set OFF (a user setting), the Audible Alarm will emit a
continuous tone for 30 seconds or until acknowledged by
pressing the Advance (Front) button.
If you descend below the required decompression ceiling
before 5 minutes have elapsed, the Versa Pro will continue to
function in Decompression Dive Mode. In this case, no off-
gassing credit will be given, and for each minute above the
ceiling 1
1
/
2
minutes of
Penalty Time
will be added to
Required Stop Time.
The added Penalty (decompression) Time will have to be
'worked off' first, before obtaining off-gassing credit. Once
the Penalty Time is worked-off, and off-gassing credit begins,
required decompression Stop Depths and Time will decrease
toward zero, then the Tissue Loading Bar Graph will recede
into the yellow Caution Zone and the Versa Pro will revert to
the No Decompression Dive Mode.
NOTE: Upon entry into Delayed Violation Modes,
the red LED warning light will light and the Audible
Alarm will sound, even if it is user Set OFF. It
cannot be turned off (acknowledged) by pressing
the Advance (Front) button.