3. Installation
The reader is intended for wall fastening upon a 60 mm flush socket. In case of surface mounting,
the lower part of the housing can be replaced by surface frame ID APR-A, which is available as an
accessory part.
Important hints:
l
The reader should not be installed directly on conducting materials, such as metallic
surfaces, metal grids (armouring) or metallized surfaces, since these surfaces lead to a
reduction in the reading range. Please keep a minimum distance of 3 cm.
l
Should there be any necessity for installation on a metallic surface, the surface frame
ID APR-A may be used in order to keep the minimum distance.
l
Der spatial distance between neighbouring readers of similar types should be at least
30 cm.
l
Prior to the final installation, the intended place of installation should be checked with
regard to its capability.
l
The housing opening (A), (see illustr. 1) has to be mounted pointing downwards!
Illustration 1: mounting direction (A) downwards