background image

OASIS

®

 VERSACOOLER

®

II MODELS 

PACSL, P8ACSL, P8ACSLEE, PF8ACSL, PF8ACSLEE, PV8ACSL, PVF8ACSL, PGACSL, PG8ACSL 

SUNROC MODELS ADA8ACB, ADA8ACBHF, ADAF8ACB, ADAF8ACBHF 

 

 INSTRUCTIONS 

A.

 

INSPECTION 

Inspect the water cooler, water fountain and cartons for evidence of rough handling and concealed damage.  Damage claims should be filed with the 
carrier. 

B.

 

TO PUT WATER COOLER AND FOUNTAIN INTO SERVICE 

1.

 

NOTE:

  The following states require a licensed plumber to install cooler; AG, GA, MA, MI, OK, RI, SC, SD, TX, VT and WI.

 

CA, KS, MN, NM and OR allow for a state-registered installer or contractor as well.  State and local plumbing codes may prohibit the use of 
saddle tapping valves for water line connection in some applications.  All connections must conform to applicable plumbing codes. 

2.

 

The P8ACSL/ADA8ACB is composed of a water cooler and a water fountain. The water cooler contains the refrigeration system and is 
always mounted on the right side. This unit can be configured with the water cooler high or low.  Refer to the proper roughing in drawing for 
location of plumbing and electrical service. 

3.

 

FLUSH BUILDING WATER SUPPLY BEFORE INSTALLING UNIT. 

4.

 

Install wall hangers as shown on the desired roughing in drawing.  Wall hangers are shipped fastened to the backs of the unit.  Units with 
factory installed filters have additional instructions on a label inside of the access panel.  Read these before installing the unit. 

5.

 

To configure this cooler for right side high or right side low installation, refer to the details below.  The bottom screws of the 
appropriate side panel may be temporarily removed to install the patch plate.  Assemble the drains as shown below, matching the 
position of the gaskets to the contour of the cooler tops. 

6.

 

Mount the water cooler on the right hanger. 

7.

 

Straighten the inlet “Water In” tube in the water fountain.  Mount the water fountain on left side hanger while routing the “Water In” tube 
through the access hole to the water cooler.  Remove the plug from the “Drain/Remote Cold Water” connection and insert the “Water In” tube. 

8.

 

All provided waste drain parts for field installation are packed in the water fountain.  Assemble the drain per the appropriate 
roughing in drawing.  The short leg of the crossover piece will be on the water cooler side.  When the unit has an internal waste trap, 
the trap should be wrapped with insulating tape to prevent sweating.  The use of the 1-3/4” knockout for a waste line is not 
recommended because of a potential conflict with ADA* toe space requirements.  Check with your local building code inspector for 
approval. 

9.

 

Install a shut off valve in water supply line.  Remove the strainer from the cooler “Water Supply” tube.  Solder 3/8” inlet tube extension 
(furnished) with lead free solder to “Water Supply” tube and insert the strainer in open end of extension.  Connect extension to shut off valve.  
To allow access to strainer for service, this connection should not be a solder or flare joint.  To ease removal of the strainer, a sheet metal 
screw may be lightly threaded into the open end. 

10.

 

Rotate the fan blade by hand to see that it is free of obstructions. 

11.

 

Check the available power supply against the water cooler data plate to assure correct electrical service.  Plug power supply cord into wall 
outlet.  The rear most 1-3/8 diameter knockout in the frame bottom is for an externally located electrical supply.  Make sure the knockout hole 
edge is smooth and free of any burrs.  Use of a Heyco busing #2184 in the knocked out hole is recommended in order to prevent damage to the 
service cord and to close up excess opening around the cord.  Route the cord so it does not interfere with ADA* space requirements. 

12.

 

To fill the cold water tank on the water cooler, open the water supply line shut-off and push any one of the front pushbuttons to allow water to 
flow to the bubbler.  On The EE model, actuate the solenoid by holding one hand approximately 3 inches from the infrared sensor.  Run water 
until stream is free of bubbles. 

13.

 

To adjust bubbler stream: 

a)

 

All pushbutton models are equipped with a cartridge regulator.  The P8ACSL/ADA8ACB and PF8ACSL/ADAF8ACB have a slot in the 
shelf below the pushbuttons.  Insert a screwdriver in this slot to adjust regulator.  Turn adjustment clockwise to increase stream height.  
To access PV8ACSL and PFV8ACSL adjustment, remove the bezel and button from the front of the cooler. 

b)

 

Electric eye (EE or HF) models have a regulator built into the bubbler.  If adjustment is needed, insert a 5/64 wrench approximately 1-
1/8" into the bubbler nozzle opening until it bottoms out and is seated in an adjust screw.  Turn the adjust screw clockwise to reduce the 
stream height or counterclockwise to increase the height.  Note, less than one turn is required to go from a closed to a wide open flow.  
Do not overtighten the adjuster in the closed position as stripping the hex impression in the adjust screw may result. 

14.

 

To adjust the beam range of the sensor (EE or HF models only): 

a)

 

Shut off the water and power supplies. 

b)

 

Remove the two screws from the top front. 

c)

 

Remove the eight screws from the bottom of the nose that holds the nose to the shelf. 

d)

 

Remove the nose to gain access to sensor adjusting screw located between the two lenses. 

e)

 

The screw can be turned a maximum of ¾ turns.  Turn screw counterclockwise to decrease range.  The sensor has an adjustable range of 
24” to 48”.  It is factory set at 27”.  There is a non-adjustable on-time delay of .75 seconds to prevent nuisance actuation of the solenoid 
valve should someone walk by.  After drinking, the water will shut off immediately after walking away.  Maximum run time is 30 
seconds should someone tamper with the sensor.  NOTE:  Walls with a reflective finish, i.e., ceramic tile, across from the sensor may 
cause false actuation no matter what the sensor adjustment is for distance.  Therefore, do not install the unit in such an area or dull the 
surface of the wall so it will not reflect light. 

C.

 

MAINTENANCE 

The only maintenance operation required is the removal of dirt and lint from the condenser of the water cooler.  Inspection should be made at 3-
month intervals.  Disconnect the power supply cord, then clean the condenser with a small stiff non-wire brush when required.  Observance of this 
procedure will ensure adequate air circulation through the condenser so operation is efficient and economical. 
 

Содержание P8ACSL

Страница 1: ...ee that it is free of obstructions 11 Check the available power supply against the water cooler data plate to assure correct electrical service Plug power supply cord into wall outlet The rear most 1 3 8 diameter knockout in the frame bottom is for an externally located electrical supply Make sure the knockout hole edge is smooth and free of any burrs Use of a Heyco busing 2184 in the knocked out ...

Страница 2: ...ain WATER IN tube then push and hold push button on the water fountain until water fountain is completely drained 4 Disconnect the power supply cords 5 Plug both water cooler DRAIN REMOTE COLD WATER tube and water fountain WATER IN tube 6 ALWAYS DRAIN ALL WATER WHEN FREEZING TEMPERATURES ARE ANTICIPATED AND BEFORE SHIPPING THE WATER COOLER American With Disabilities Act WARNING The warranty and th...

Страница 3: ......

Страница 4: ......

Страница 5: ... II products If the cooler outlet does not have two useable plugs an outlet splitter will need to be used If installed onto a refrigerated cooler chilled water can be dispensed through the VersaFiller Otherwise room temperature water will be dispensed The VersaFiller is shipped partially assembled On the combo units the cooler is plumbed and ready to attach to the VersaFiller When completed the fi...

Страница 6: ...ver 15 torx bit driver 38 of OD plastic tubing with 19 of sponge tubing insulation included with Versafiller ready coolers Anti splash grate Drip tray What s Included Tools required Installation instructions Section 1 Getting Started Anti Splash grate screws 2 Snap bushing Quick connect tee fitting only required on split level units Top cap VersaFiller Hands Free Sports Bottle Filler with wrapper ...

Страница 7: ...Oasis PWEBF Versacooler II Models PAC P8AC with Hands Free VersaFiller Section 2 Rough In Drawing 3 ...

Страница 8: ...asis PWEBF Versacooler II Split Level Models with Hands Free VersaFiller Section 2 Rough In Drawing On split level models the VersaFiller must be mounted on the low unit in order to meet ADA guidelines 4 ...

Страница 9: ...ligned with the left side of unit and wall SEE NEXT PAGE FOR TEMPLATE 4 Mark hole location 5 Remove top from unit Template Mark hole location Drill Install bushing Remove top from cooler by removing six 15 torx head screws on sides of top Section 3 Installation Note Proceed to Sect 3B Step 5 if the cooler is purchased VersaFiller ready 6 Using a step drill bit or 7 8 punch die make a 7 8 hole thro...

Страница 10: ...LER TOP USE THIS TEMPLATE TO MARK THE HOLE LOCATION ON COOLER TOP 3 1 4 from side 2 1 8 from back Mark this center point on the top Remove the top from the cooler Then create a 7 8 diameter hole through the top at the marked center point step drill bit or punch die 6 ...

Страница 11: ...d water from the cooling tank to the Versafiller OD tube to connect to Versafiller Note If you are retrofitting the Versafiller to an existing cooler follow the instructions starting on the next page For split level Versafiller ready coolers the tube to plumb in the Versafiller is packaged in the dummy unit Remove tube from bag First remove plug from fitting on tank drain Next insert end of tube i...

Страница 12: ... branch of the tee will connect to the Versafiller If a filter is being installed cut a piece of tubing about 3 long to insert flow switch right after filter and before tee This allows Versafiller counter to accurately calculate amount of water passing through filter Tube to connect valve on dummy unit Tube to connect Versafiller Tube to connect chilled water to dummy unit and Versafiller 8 ...

Страница 13: ... tank is non pressurized then go to the Pressurizing the cooling tank addendum section Otherwise proceed to step 1 below Non pressurized units are single units made since December of 2009 Refer to the schematic below to identify the system that you have PRESSURIZED COOLING TANK Cooling tank Water valve regulator Supply Water NON PRESSURIZED COOLING TANK Cooling tank Water valve regulator Supply Wa...

Страница 14: ...branch of the TEE Connect the other end of the TEE to the tank outlet tubing tube that was disconnected from the elbow 32 tubing 6 tubing 4 Route the TEE and tubing under the waste drain and connect the 6 length to the water valve elbow TEE Go to Step 5 Final steps for both product families Water valve elbow Section 3 Installation For the P8AC Version Versacooler II 10 ...

Страница 15: ...ube with a tubing cutter Cut where there is at least 1 inch of straight tubing on each side of the cut 4 Install TEE fitting by connecting the copper tubing to each end Then install the 32 piece of plastic tubing to the TEE branch 32 plastic tubing supplied Section 3 Installation For the P8AM Version Versacooler I 11 ...

Страница 16: ...nnect tee and white tube packed with bottle filler per schematic below Attach top to cooler If flow switch was installed cord from flow switch must also pass through this bushing Section 3 Installation Final steps for both product families TIP For the P8AM it is easier to connect the outlet tube to the bubbler if the front nose is removed 12 ...

Страница 17: ...Section 3 Installation C Mounting the frame to the wall 1 Place rubber gasket on top of the cooler so it is centered left right and against the wall 13 ...

Страница 18: ...e proper securing location Make sure to pull the plastic tubing and flow switch wire if applicable up through the hole in the frame 4 Slide sponge tubing insulation over water line Connect the tubing to the INLET of the solenoid on the back of the Hands free VersaFiller assembly and flow switch connector into port on circuit board Connect tube to inlet of the valve Plastic tubing Rear view of Vers...

Страница 19: ...ews 5 Set the VersaFiller cabinet into place As you do feed the terminals on the power supply power cord and the 30 76 cm long green ground wire through the bushing on the cooler top MAKE SURE the cabinet fits into the groove in the rubber gasket on both sides and front of the wrapper VersaFiller cabinet Groove in the gasket Section 3 Installation 15 ...

Страница 20: ...power cord ground located on cooler frame 10 Plug in bottle filler cord The program should be set up specific for that installation See the program guide on the next page Section 3 Installation 11 Turn ON water supply and check for leaks Place a container in the alcove to release any trapped air from the system Plug in the power cord and replace the front panel 12 If everything works correctly pla...

Страница 21: ...Gallons Unfiltered unit Filter Capacity 1250 gallons 4731 liters for a VersaFilter Pushbutton Factory default program settings are Bottle Count 0 5L 1 Bottle Flow Rate 1 2 GPM 20 second maximum dispense time To change the program settings follow these steps 17 ...

Страница 22: ...inlet quick connect elbow located left side of water valve facing the front of the cooler Set tubing aside careful to not contaminate water contact end Unplug tubing from quick connect elbow leading to cooling tank inlet STEP 2 Addendum Section Pressurizing Cooling Tank Unit as it appears with top removed STEP 1 18 ...

Страница 23: ...w leading to the cooling tank from step 2 STEP 3 STEP 4 Unplug tubing that is connected to the water valve outlet quick connect elbow located on the right side of valve facing the cooler STEP 5 Connect tubing from step 4 to quick connect elbow on the left side of the valve 19 ...

Страница 24: ...bow on the right side of the valve be sure to route the tubing under existing tubing installed in step 4 as shown Step 8 Using tubing that is connected to the quick connect elbow left side of valve done in step 4 and plug the other end into the quick connect fitting at the top of the cooling tank Return to Section 3 B Connecting the water line 20 ...

Страница 25: ... KIT P N 036752 001 Gasket Elkay Halsey Taylor P N 036689 201 replaces item 13 KIT P N 036752 002 Oasis Aqua Pointe Versacooler and VersaFiller are registered trademarks of LVD Acquisition LLC dba Oasis International A WBENC Certified Women s Business Enterprise Haws is a registered trademark of HAWS Corporation Elkay and Halsey Taylor are registered trademarks owned or licensed by Elkay Sales Inc...

Страница 26: ...TRONICS Factory default program settings are Bottle Count 0 5L 1 Bottle Flow Rate 1 2 GPM 20 second maximum dispense time To change the program settings follow these steps For Hands free VersaFiller models top cap will need to be set aside until programming is complete Remove top cap by unscrewing two 2 T15 torx screws if needed Remove wire tie bundling pushbutton inside bottle filler and feed it ...