manualshive.com logo in svg
background image

 SCC P/N    

20-30109 

READ AND SAVE THESE INSTRUCTIONS 

Rev C Date: 10.1.2019 

I:\Oper Manual\Oasis\FSC463R Ref Grab-N-Go 20-30109.pub 

 

Merchandiser Shown With Product  

For Illustrative Purposes Only 

MODEL FSC463R REFRIGERATED GRAB-N-GO MERCHANDISER 

888 E. Porter Road ∙ Muskegon, MI  49441  Phone: 231.798.8888  Fax: 231.798.4960  www.structuralconcepts.com

 

INSTALLATION &  

OPERATING MANUAL 

Содержание FSC463R

Страница 1: ...l Oasis FSC463R Ref Grab N Go 20 30109 pub Merchandiser Shown With Product For Illustrative Purposes Only MODEL FSC463R REFRIGERATED GRAB N GO MERCHANDISER 888 E Porter Road Muskegon MI 49441 Phone 231 798 8888 Fax 231 798 4960 www structuralconcepts com INSTALLATION OPERATING MANUAL ...

Страница 2: ... PERFORMED BY STORE PERSONNEL EXTERIOR INTERIOR GENERAL CLEANING TO BE PERFORMED BY TRAINED SERVICE PROVIDERS ONLY TROUBLESHOOTING TO BE PERFORMED BY STORE PERSONNEL UNLESS STATED OTHERWISE TROUBLESHOOTING TO BE PERFORMED BY TRAINED SERVICE PROVIDERS ONLY TROUBLESHOOTING BY TRAINED SERVICE PROVIDERS ONLY CONDENSING SYSTEM TROUBLESHOOTING BY TRAINED SERVICE PROVIDERS ONLY EVAPORATOR SYSTEM PREVENTI...

Страница 3: ...heet contains important warnings to prevent injury or death Please read carefully PRECAUTIONS MAINTENANCE WIRING DIAGRAM INFORMATION See next page for PRECAUTIONS MAINTENANCE and WIRING DIAGRAM information WARNING Hazardous moving parts Do not operate unit with covers removed Fan blades may be exposed when deck panel is removed Disconnect power before removing deck panel WARNING Risk of electric s...

Страница 4: ... overall design Any replacements must meet factory specifications CAUTION PRECAUTIONS This sheet contains important precautions to prevent damage to unit or merchandise Please read carefully See previous page for specifics on OVERVIEW CONDITION TYPE COMPLIANCE and WARNINGS WIRING DIAGRAM Each case has its own wiring diagram folded and in its own packet Wiring diagram placement may vary it may be p...

Страница 5: ...els from case before removing from skid to prevent buckling Illustrations below show case being removed from skid REMOVAL OF CASE FROM SKID POSITIONING UNIT 5 Place case in proper location Plug cord into certified electrical outlet with ground 2 Positioning Unit Place unit into desired location before leveling See next page for specifics about leveling Slide Skid Out From Under Case ...

Страница 6: ... and plumb You may need to remove front and or rear toe kick to access levelers Use adjustable wrench and or a pry bar to adjust leveler Do not use Pry Bar on Toe Kick as it will buckle Do not use Pry Bar on End Panel It may chip Use Pry Bar ONLY on Base Frame to avoid damaging case Pry Bar ...

Страница 7: ...firmly and pulling up and outward See illustration at top right Field Wiring Ballast Box Thermostat Controller Main Power Switch Main Power Switch 3 Main Power Switch For self contained cases the main power switch controls power to entire case If main power switch is not turned on lights will not turn on NOR will refrigeration components operate See illustration below 4 Temperature Control Illustr...

Страница 8: ...s throughs Caution If ceiling originated lines are used you MUST seal both upper and lower PVC Center Pass Through Protective Plate Shown After Removal of Knock Outs center pass throughs at entrance points with expandable foam sealant to prevent condensation in case 3 Plate Removal Note Though not required protective plate can be removed from merchandiser via four 4 screws 4 Case Underside See REF...

Страница 9: ...S DO NOT STACK PRODUCT ON DECKS HIGHER THAN UNDERSIDE OF SHELF DO NOT ALLOW PRODUCT ON DECKS TO HANG OVER PRODUCT STOP ACCEPTABLE PRODUCT PLACEMENT 1 Min SIDE VIEW SIDE VIEW Do Not Allow Product On Decks To Hang Over Product Stop Do Not Stack Product Nearer Than 1 To Underside of Plenum Do Not Stack Product On Decks Higher Than The Underside Of Lower Shelf Do Not Stack Product Nearer Than 1 To Und...

Страница 10: ...g mechanism s flat bar into the bracket with slot at center of case See illustration at top right and mid right 3 Security Cover Removal Optional A With key inserted in the lock rotate the locking mechanism s flat bar out of the bracket with slot as shown in top right illustration Digital Thermometer B Lean security cover away from header at top of unit C Holding security cover handles or grasping...

Страница 11: ...ns will be operational To verify fans are operational lift up deck pans check to see that the coil fans are functioning properly See illustration below partially disassembled for illustrative purposes only Evaporator Coil Fans Illustration Shown May Not Exactly Reflect Every Feature or Option of Your Particular Case TXV Drain Refrigeration Lines Route ...

Страница 12: ... set temperature and airflow 2 Shelf Bracket Assembly Shelf bracket assemblies ARE NOT to be adjusted or moved from their factory determined slots Item 3 below provides an exception to this guideline 3 Shelf Bracket Assembly Removal Cleaning can usually be accomplished WITHOUT the removal of the shelf bracket assembly Should stubborn stains or residue require removal of shelf bracket assembly howe...

Страница 13: ...ed in upper section of the case in front of honeycomb and under shelving 3 LED Light Fixture Removal and Replacement This case is provided with mini LED lights which will rarely require change out To remove LED light fixture disconnect the existing LED light from its brackets Replace Note LED Plug must be connected in a specific manner or they will not work Oval form of plug must connect to oval f...

Страница 14: ... shows location of refrigeration lines for self contained operation Two 2 drains accessible from top of unit by lifting up decking See POWER UP CHECK EVAPORATOR FAN AREA section in this manual for under decking drain illustration Case Rear Drain Drain Line To Position Over Condensate Pan Refrigeration Lines Case Front Drain Electrical Box Center Pass Through Covered Drain Line To Position Over Con...

Страница 15: ...lter Dryer Electrical Starter Unit Condenser Coil Housing Condenser Coil Fan Fan Housing Motor Refrigeration Lines Sight Glass Compressor Pan Self Contained Merchandiser s Condensate Unit Illustrated Parts Breakdown Assembly disassembly and servicing to be performed by licensed refrigeration contractor ...

Страница 16: ... and water solution and a non abrasive soft cloth For stubborn stains use a nylon brush DO NOT use abrasive cleaners or Brillo pads as these can destroy the shelf bracket finish Caution After removing and cleaning shelving bracket assemblies YOU MUST return them to THE SAME EXACT slots they were in prior to their removal Reconnect connectors into LED plugs after shelving bracket assemblies are in ...

Страница 17: ...l outlet before beginning fan shroud and surrounding tub area cleaning 1 Turn off power 2 Remove deck from case 3 Clean fan shroud area and surrounding tub area with moist cloth Quarterly Tub Drain Caution Due to rotating fans in area turn off case and disconnect plug from wall outlet before beginning tub drain cleaning Vacuum tub under decks Clean with soap and water solution Wipe dry with clean ...

Страница 18: ...ht The power end of cord is to connect at the red dot marker at the end of the LED lamp See MAINTENANCE FUNDAMENTALS SHELF BRACKET ASSEMBLY REMOVAL LIGHT FIXTURES section in this manual for more specifics including illustrations If case light still do not come on call service provider Case is Not Holding Proper Temperature If a large amount of warm product was added to the case it will take time f...

Страница 19: ...rs Check motor shaft for bearing wear Check that fan motors are securely mounted in brackets Verify that fan blades are securely mounted to fan motor Check that nothing is preventing blade rotation Check that the fan shroud is properly secured Fans Are Not Working Check that the MAIN power switch is on Check that fans are plugged in at the fan shroud Check for foreign material obstructing fan perf...

Страница 20: ...ons If case light still do not come on call SCC Technical Service phone number listed on last page of this operating manual Control Display Is Flashing See your case s serial label for your model s specified settings See SERIAL LABEL LOCATION INFORMATION LISTED TECH INFO SERVICE for label location etc Case Is Not Holding Temperature If a large amount of warm product was added to the case it will t...

Страница 21: ...non condensable is not in the system Check that Liquid Line Drier is not plugged Check that there are no close offs around Condensing Coil Check Set Point Temp it may be adjusted too high Check System Operating Temperatures Check that Store Ambient Temperature isn t above maximum allowed See Overview and Warnings Section Head Pressure Too Low Check that Refrigerant Charge isn t too low Check that ...

Страница 22: ...at High Superheat doesn t need adjusting Check that the Thermostatic Element charge isn t depleted Check that there is air no seepage of air around Condensing Coil Check that the Coil is not iced up High Suction Pressure Check that Refrigerant Charge isn t too high Check that Compressor Valves aren t bad Check that the Cooling Load isn t high Check that Superheat Adjustment isn t low Check TXV Bul...

Страница 23: ...tructions as to proper dilution safety precautions and scrubbing method After thoroughly cleaning pan with scrub brush and solution rinse thoroughly with clean water in spray bottle and wipe dry with sponge or paper towel Use moist cloth to wipe off dust debris that collects on various parts fans sight glass overflow pan etc Slide refrigeration assembly back under case Replace front panel and lowe...

Страница 24: ...to collapse the honeycomb to allow it to be pulled out of honeycomb retainer C Pry downward and away from honeycomb retainer Clean honeycomb with warm water and soap solution Submerse if necessary Use brush to A B C D E F dislodge stubborn or sticky residue Dry by using vac uum s blow mode 2 Honeycomb Air Diffuser Installation D Squeeze honeycomb into the honeycomb retainer E Carefully slide honey...

Страница 25: ...perature refrigeration information as well as regulatory standards to which the case conforms For additional technical information and service see the TECHNICAL SERVICE page in this manual for instructions on contacting Structural Concepts Technical Service Department See images below for samples of both refrigerated and non refrigerated serial labels Sample Serial Label For Refrigerated Case Samp...

Страница 26: ...eing made will resume 3 If the instrument is switched off before pressing the Prg key all modifications to parameters will be lost Set Set aux Prg mute def Prg mute Set Set def Set aux aux def Set Prg mute Structural Concepts Corp 888 E Porter Rd Muskegon MI 49441 Ph 231 798 8888 Fax 231 798 0393 www structuralconcepts com I Oper Manuals PUB Templates Carel Controller Carel Controller IR33 pub Thi...

Страница 27: ...eset reset HACCP alarms reset temp monitoring Summary Table of Alarm and Signals Display Buzzer and Relay Integrated Electronic Microprocessor Controller Read And Save These Instructions Page 2 of 3 User Interface Display 27 ...

Страница 28: ...F F 50 200 dP1 Maximum defrost duration evaporator min F 1 250 d6 Display on hold during defrost C 0 2 dd Dripping time after defrost min F 0 15 d 1 Display of defrost probe 1 C F F 28 For Case Specific Defaults See Serial Label Located Near Electrical Access On Your Case For Additional Technical Information Call Structural Concepts Technical Service Dept at 1 800 433 9489 Unit Of Measure Read And...

Страница 29: ...sonable attorney fees and costs Remedies of SCC SCC s rights and remedies shall be cumulative and may be exercised from time to time In a proceeding or action relating to the breach of this Agreement by Purchaser Purchaser shall reimburse SCC for reasonable costs and attorney s fees incurred by SCC No waiver by SCC of any breach of Purchaser shall be effective unless in writing nor operate as a wa...