031666-009 Rev C 2000
Page 3 of 11
FILTER INSTALLATION
WARNING - Failure to follow these procedures will affect water treatment system performance
and void the warranty.
Unscrew the cartridge vessels from the manifold.
Open the upper end of the bagged filter cartridge
exposing the o-rings on the filter cartridge. Slide
down the bag enough to lubricate the o-rings
using Dow Corning
®
Compound 111 or
equivalent. It is recommended that you do not
touch the filter cartridge with your bare hands.
Insert the cartridge into the head with a twisting
and pushing motion. Discard the bag.
Screw the cartridge vessels back into the
manifold tightening enough to ensure a good seal
between the head and the vessel.
Install the Quad filter cartridge in the vessel using
techniques previously described.
NOTE: TIGHTEN FILTER HOUSINGS BY HAND
ONLY. Do not use tools as they will over-tighten
and damage housings.
Dow Corning
®
is a registered trademark of the
Dow Corning Corporation.
INTER-COMPONENT CONNECTIONS
Connections between the cold water supply line, filtration unit and optional accessories are
accomplished using plastic tubing and push-together quick-connect type fittings.
PLASTIC TUBING
Cut tube ends square and straight. Do not
deform the tube (i.e., cause tube to compress its
diameter so it is no longer round).
Make sure the outer surface of the tube is clear
of marks or scratches for a length equal to twice
the tube diameter. This allows the “O” ring to
seat properly against the tube (See Figure 2).
Avoid sharp changes in direction when routing
the tubing. Sharp turns cause the tubing to flex
and deform which reduces its flow capacity.
QUICK-CONNECT FITTINGS
Fittings consist of two parts: a Body and a
colored Collet. The Collet color corresponds to
the tubing color to be used at that connection
(See Figure 2).
To install a tube, push it through the Collet until it
seats firmly at the bottom of the fitting.
To remove a tube, push and hold the Collet
against the Body while pulling the tube out.
NOTE: Systems are shipped with a plug in each
fitting. Remove a plug in the same manner as a
tube.
Push tube through Collet into Body Tube must seat firmly at bottom of fitting
Push Collet against Body to release tube.
Figure 2 How to Use Quick-Connect Fittings