18
ProMax Garden Automatic 3500/4000/5000/6000
Switching on the pump following a mal-
function
The LEDS yellow and red are lit when the
pump switches off due to a malfunction.
• Press the ON/OFF button for at least
3 s, but not longer than 6 s to switch the
pump on again.
REMEDY OF FAULTS
W A R N I N G
Dangerous electrical voltage!
Death or severe injury from electrocution.
Prior to starting work:
• Switch off the unit, disconnect the power plug and secure the unit from being switched
on again.
• Before stepping into or reaching into the water, switch off all units located in the water.
On completion of the work:
• Restore all the prerequisites for start-up.
Malfunction
Cause
Remedy
Pump does not start. The pump is switched off.
Switch on the pump.
Power supply interrupted
Check the electrical plug
connections.
The fault current protection de-
vice has tripped.
Switch off the pump and
disconnect the power plug.
Then contact the OASE
Service.
The pump has been out of ser-
vice for a prolonged time (e.g.
during the winter). The impeller is
stuck.
Insert a screwdriver
through the rear service
hole, turn to release the im-
peller.
The pump is not de-
livering, or the deliv-
ered quantity is insuf-
ficient.
The pump is not sufficiently filled
with water.
Fill the pump and ensure
that the water does not flow
out on the pressure side.
Pressure line blocked
•Open the water with-
drawal point on the
pressure side.
•Route the pressure hose
without kinks.
Suction line blocked
•Clean the connection on
the suction side and the
suction line
•Route the suction hose
without kinks
Leak on the suction side
Eliminate leak on the suc-
tion side