Operating status and attendant LED displays
LED
Operating status
User
Blue
Yel-
low
Red
Flashing fre-
quency
�
�
�
–
Pump is operational.
Switch on the
pump.
�
�
�
–
No malfunctions, pump is
running.
�
�
�
4× per second No malfunctions, the pump
will soon switch to standby.
�
�
�
–
No malfunctions, the pump
is in standby.
�
�
�
–
Pump is not taking in water.
1st stage - dry run protection
Wait
�
�
�
1× per second Pump is not taking in water
•2nd stage - dry run pro-
tection
Wait
�
�
�
2× per second Pump is not taking in water.
•3rd stage - dry run pro-
tection
•In the 4th stage the pump
switches into waiting
mode.
Wait
�
�
�
3× per sec-
ond, each
LED alter-
nately
4th stage - dry run protec-
tion.
The pump is in waiting mode
for 120 s, then the cycle
starts again, max. 2×
Wait or find the
cause.
�
�
�
–
Malfunction, pump has run
through cycle 3×
Disconnect the
power plug, check
the suction side,
reconnect the
power plug.
�
�
�
1× per second Test cycle. Leakage protec-
tion starts after 60 min, max.
2 cycles.
Wait
�
�
�
–
Malfunction, 18 un-
successful start attempts
Disconnect the
power plug, check
the pressure side,
reconnect the
power plug.
�
LED on
�
LED off
�
LED flashing