- EN -
56
6.8 Sy
stem
messages
The 4-digit sy
stem me
ssag
e is displayed
as tw
o g
roup
s of two digits appea
ring in
su
ccessio
n.
S
ys
tem mess
ag
e
Func
tio
n
s
th
at
are still a
vail
abl
e
Possible
cause
Reme
d
y
Reset
ting
the
s
ys
tem
messa
ge
Er11
Container cover
ra
ised
Manual cleaning
(onl
y nozzles,
filter drum not
rotating)
Container cover
ra
ised
Refit the contain
er cover
Automatic w
he
n t
he
container cover is
replaced
Container cover i
ncorrectl
y fitted
Turn th
e contain
er cover aro
und
so that the magn
ets in
the container cover are located ov
er the signal box
Signal box not co
nnected
Connect the sign
al box to the cont
rol s
ystem
Er22
Water tempe
ratu
re > 12 °C
AND the last aut
omatic
cleaning process w
as car
ried
out more th
an 24
hours ago.
Manual cleaning
Automatic mode
Time-depen
dent
cleaning
Screen elements leaking
Check screen elements, replace if necessar
y
Pr
ess
key
for
5 s
Automatic as soon as
the level detection
device is triggered
Drum seal leaking
Check the drum
seal
Level detection device stuck or defective
Clean the level detection device to ensure that t
he
mechanics operate freel
y,
replace
if necessary
Level detection device set incorrectly
Adjust the level d
etection device (
→
Adjusting the level
detection device)
Manual cleaning
Automatic mode
24 hour check m
ode is active and time-depende
nt
cleaning
is deactivated.
Time-depen
dent
cleaning is automatically
activated b
y
floats after check mode.
Er33
20 cleaning cy
cle
s in
success
ion
Manual cleaning
Time-depen
dent
cleaning
Level detection device stuck or defective
Clean the level detection device to ensure that t
he
mechanics operate freel
y,
replace
if necessary
Pr
ess
key
for
5
s
Screen elements heavily
soiled
Clean/descale the screen element
s (
→
Removing/fitting a
screen element)
Rinsing pump no
t operating
Clean the bottom
of the c
ontainer,
clean the rinsing
pump (
→
Cleani
ng the rinsing pu
mp)
Check the pump
connection
Rinsing nozzle clogged
Clean the rinsing
nozzle
Filter drum not
ro
tating
Check the motor
connection
Check the rotatin
g movement of t
he filter drum.
Tip: Mark the filter drum a
nd check on the basis of the
markings if the dr
um rotates.
Level detection device set too low
Adjust the level d
etection device (
→
Adjusting the level
detection device)
Water level in the s
ystem too hig
h:
Outlet pipes soiled
Clean outlet pipe
s
Outlet opening t
o
o small
Enlarge outlet op
ening
Excessive flow
q
uantit
y (p
ump ca
pacity
t
oo high)
Reduce flo
w
qua
ntit
y (adjust pum
p capacity)
The pond
water
is ver
y dirt
y and t
he filter pump is
convey
ing
an e
xcessive amount of dirt.
Thorou
ghl
y clean
the pond.
Install the pump in an elevated po
sition.
A large amount o
f dirt has entere
d
the filter s
ystem,
w
a
ter
is flow
ing over (i
nstead of throu
g
h) the foam filter
s.
Clean foam filter
s
On|O
ff
On|O
ff
Содержание ProfiClear Premium Compact
Страница 2: ... 2 A yy yy yy ProfiClear0100 B ProfiClear0108 ...
Страница 3: ... 3 C yy ProfiClear0107 D ProiiClear0106 E yy ProfiClear0101 F yy G yy ProfiClear0103 ProfiClear0102 ...
Страница 4: ... 4 H ProfiClear0081 ...
Страница 5: ... 5 I ProfiClear0082 ...
Страница 6: ... 6 J BTC0030 K BTC0027 ...
Страница 7: ... 7 L M BTC0019 BTC0022 N O ProfiClear0040 BTC0018 P ProfiClear0105 ...
Страница 8: ... 8 Q R BTC0031 ProfiClear0044 S PrifiClear0083 T BTC0025 ...
Страница 9: ... 9 U ProfiClear0084 V ProfiClear0085 W X BTC0023 BTC0024 ...
Страница 10: ... 10 Y ProfiClear0104 ...
Страница 309: ...309 ProfiClear0066 ...
Страница 310: ...310 ProfiClear0074 ...
Страница 318: ......
Страница 319: ......
Страница 320: ...42887 11 15 ...