- EN -
18
3.2
Unit configuration
C
Description
1
Container cover
2
Signal box with level detection device (3) and temperature probe (7)
•
The signal box is connected to the control system (30, 32)
3
Level detection device
•
Signals the water level in the filter
system
4
Rollers for guiding the filter drum
6
Filter drum with 8 screen elements
•
Screen elements for coarse dirt down to
60 µm
in size,
30 + 150 µm
also available as an option
7
Temperature probe
•
monitors the water temperature
8
Air hose
∅
⅜
in (
∅
9 mm)
9
Hel-X 13 biomedia in
Moving Bed
filter chamber
10
2 × outlet
∅
4 in (DN 110)
11
Aerator rod
12
Meshed tube
•
Prevents the
Hel-X- biomedia from being flushed out
13
Rinsing pump for supplying the rinsing device (24)
14
1 × dirt outlet with slide valve
∅
3 in (DN 75)
15
2 × adapter, 2 × 30° inlet bend with union nut
For connection of UVC clarifier Bitron to
∅
1½ in (
∅
38 mm) connections (18)
16
Connection set for filter pumps
•
1 × hose connector
∅
2 in (
∅
50 mm)
, 1 × union nut for hose connector, 1
×
hose clip
∅
1.6 … 2.3 in
(
∅
40 … 60 mm)
, 1 × flat gasket
2.2 × 1.7 × 0.1 in (56 × 43 × 3 mm)
17
1 × inlet
∅
2 in (
∅
50 mm)
•
For connecting a filter pump
18
2 × inlet
∅
1½ in (
∅
38 mm)
, closed with sealing plugs
•
For
connecting an optional UVC clarifier
Bitron
20
1 × optional inlet
∅
2 in (
∅
50 mm)
•
Must be cut out, if required (connection not included in the scope of delivery)
21
1 × coarse dirt outlet
∅
4 in (DN 110)
22
Drum motor for filter drum
•
The motor is
connected to the control system (30, 31)
23
Dirt channel
•
Collects the coarse dirt and rinsing water from the screen elements (6)
24
Rinsing device
•
Sprays water at high pressure onto the screen elements (6) to rinse off the coarse dirt
25
Grease for the drum seal
27
Transition piece
∅
⅜
in to
∅
⅛
in (
∅
9 mm to
∅
4 mm)
28
Y piece
29
2 × cable binder for fastening the air hoses to the Y piece
30
Control system with
EGC
box
•
Allows integration with cables into an
EGC
network.
31
Plug for connecting the drum motor
32
Socket for connecting the signal box
33
Mains connection cable
34
Connector for rinsing pump
35
Fuse holder
•
Fuse protection of the control system with safety fuse
5 ×
20 mm, T16 A, 250 V
36
2 x cap, cap nut for fastening the
EGC
box
•
Required for mounting the EGC
box on the container wall
37
Capacitor box for the rinsing pump
38
Plug for connecting the control system (34)
39
Plug for connecting the rinsing pump
Содержание Profi Clear Premium Compact L US
Страница 1: ...Pro Clear Premium Compact L US...
Страница 2: ...2 A ProfiClear0239...
Страница 3: ...3 B ProfiClear0243...
Страница 4: ...4 C ProfiClear0279 D ProfiClear0164...
Страница 5: ...5 E ProfiClear0129 F ProfiClear0130...
Страница 6: ...6 G ProfiClear0244 H ProfiClear0245 I ProfiClear0169...
Страница 7: ...7 J ProfiClear0240 K ProfiClear0280...
Страница 8: ...8 L EGC0009 M EGC0003 N ProfiClear0134...
Страница 9: ...9 O P PrifiClear0135 Q ProfiClear0041...
Страница 10: ...10 R ProfiClear0137 S ProfiClear0138...
Страница 11: ...11 T U ProfiClear0140 ProfiClear0141 V ProfiClear0139...
Страница 110: ...110 Proficlear0251 Proficlear0252...
Страница 112: ...112 Proficlear0254 Proficlear0255 Proficlear0256...
Страница 114: ...114 Proficlear0259...
Страница 116: ...76481 01 20...