11
OptiMax 85i/85/135i/135/250/285
Issue
Cause
Solution
The unit does not
start up
No mains voltage
Check the mains voltage.
Impeller unit blocked
Clean
Water flow
insufficient
Position of the flow regulator
Readjust the flow regulator.
Filter housing or impeller unit soiled, hose blocked Clean
Hose defective
Replace
Hose kinked
Route hose in a straight line
Impeller unit worn
Replace impeller unit
Only submersed
during installation
Filter housing clogged
Clean the filter housing.
TROUBLESHOOTING
REPAIR
A damaged unit cannot be repaired and
must be put out of operation. Dispose of
the unit in accordance with the regulations.
DISPOSAL
Do not dispose of this unit with domestic
waste! For disposal purposes, please use
the return system provided. Render the
unit unusable beforehand by cutting the
cables.