manualshive.com logo in svg
background image

-  EN  - 

16 

 

 

Installation and connection 

 

 

 

 

W A R N I N G

 

Possible death or severe injury from hazardous electrical voltage! 

  Prior to reaching into the water, isolate (switch off and disconnect) all units/devices used in the water. 

  Isolate the device (disconnect from the power supply) before carrying out any work on it. 

 

 

 

 

W A R N I N G

 

Death or serious injuries from hazardous electrical voltage due to operation of this unit in a swimming pond. 

  Never operate this unit in a swimming pond. 

 

 

 

Operating the unit in the pond 

 

 C 

 

  Never operate the pump in a swimming pond. 

 

  Only operate the pump when it is below the water surface level. 

 

  Only operate the pump with the filter basket fitted. 

 

  Ensure that the pump is in a secure and stable position. 

 

 

 

 

N O T E

 

If the pump is used for conveying excessively soiled water, the impeller unit will be subject to increased wear 
and will require earlier replacement. 
Remedy: 

  Thoroughly clean the pond or pool before installing the pump. 

 

Install the pump approx. 200 mm above the floor of the pond to avoid excessively soiled water from being 

drawn into the pump. 

 

 

How to proceed: 

 

 E 

 

1.  Screw the stepped hose adapter including union nut and sealing ring to the outlet. 

 

2.  Slip the hose clip over the hose, fit the hose onto the hose connector and secure with the hose clip. 

 

 

 

Install the unit at a dry place 

 

 D 

 

  Swimming pond or pool that may be accessed by people. 

–  Install the unit at least 2 m away from the water. 

 

  Do not expose the unit to direct sunlight. 

 

  Ensure that the pump is in a secure and stable position. 

 

 

How to proceed: 

 

 F 

 

1.  Remove the screws for fastening the filter basket and remove the filter basket. 

 

2.  Screw the hose connector with union nut and seal onto the inlet. 

 

3.  Slip the hose clip over the hose, fit the hose onto the hose connector and secure with the hose clip. 

 

4.  Screw the hose connector with union nut and seal onto the outlet. 

 

5.  Slip the hose clip over the hose, fit the hose onto the hose connector and secure with the hose clip. 

 

6.  Fasten the pump to a suitable base using screws (not included in the scope of delivery). 

 

 

 

 

N O T E

 

Recommendations for hoses and pipes: 

  Use 50 mm (2 ") hose connectors and hoses for a length of up to 5 m. 

  Use DN 75 or DN 100 pipes for a length greater than 5 m. 

 

Содержание Aquarius Eco Expert 28000

Страница 1: ...42423 09 16 MH Aquarius Eco Expert 22000 28000 42423 GA Aquarius_Eco_Expert_end_ 13 09 16 16 48 Seite 2...

Страница 2: ...2 A B ARS0033 ARS0034 C ARS0025 D ARS0026...

Страница 3: ...3 E ARS0027 F ARS0030...

Страница 4: ...4 G ARS0029 H ARS0028...

Страница 5: ...5 I ARS0031...

Страница 6: ...disconnect all units in the water that have a voltage of 12 V AC or 30 V DC from the power supply Only operate the unit if no persons are in the water Do not use the unit if electrical cables or housi...

Страница 7: ...carried out in accordance with these instructions Adhere to the safety information for the correct and safe use of the unit Keep these instructions in a safe place Please also hand over the instructi...

Страница 8: ...ris with a particle size of up to 4 mm Ergonomic handle for safe transport Suitable for immersed or dry installation Unique patented frost protection The pump is guaranteed to operate without damage a...

Страница 9: ...pond to avoid excessively soiled water from being drawn into the pump How to proceed E 1 Screw the stepped hose adapter including union nut and sealing ring to the outlet 2 Slip the hose clip over the...

Страница 10: ...Control is limited The unit is not protected from running dry Remedy of faults Malfunction Cause Remedy Pump does not start No mains voltage Check the mains voltage Check supply lines Pump does not de...

Страница 11: ...basket and remove the filter basket 2 Clean all parts Use a soft brush Rinse parts in clean water 3 Reassemble the unit in the reverse order Replacing the impeller unit N O T E The impeller unit is gu...

Страница 12: ...thoroughly with a soft brush and water check it for damage then store immersed in water or filled with water Do not immerse the power plug in water Repair Repair is not possible in the following cases...

Страница 13: ...ffektopptak Kapasitet Vanns yle Nedsenkningsdybde SV Typ Anslutningssp nning Effekt Matningsprestanda Vattenpelare Doppningsdjup FI Tyyppi Verkkoj nnite Ottoteho Sy tt teho Vesipylv s Upotussyvyys HU...

Страница 14: ...aks omgivelsestemperatur ved tvangskj ling Kabellengde M l Vekt SV Typ Installation p torr plats Max omgivningstemperatur vid naturlig konvektion Installation p torr plats Max omgivningstemperatur vid...

Страница 15: ...tt ned til 4 m dyp Beskytt mot direkte sollys Ikke kast i alminnelig husholdningsavfall NB Les bruksanvisningen SV Dammt t Vattent t till 4 m djup Skydda mot direkt solstr lning F r inte kastas i hush...

Страница 16: ...ur SV Rekommenderade vattenv r den ph v rde Total h rdhet Fritt klor Kloridhalt Salthalt Temperatur FI Suositellut vesiarvot ph arvo Kokonaiskovuus Vapaa kloori Kloridipitoisuus Suolapitoisuus L mp ti...

Страница 17: ...42423 10 17...

Отзывы: