background image

PX Series

USER MANUAL

www.oakworksmed.com  ·  717.235.6807

made in the USA

with US & imported parts

PT Series

OAKWORKS

®

 

PX & PT Tables

Содержание PX Series

Страница 1: ...PX Series USER MANUAL www oakworksmed com 717 235 6807 made in the USA with US imported parts PT Series OAKWORKS PX PT Tables...

Страница 2: ...within this document is subject to change without notice and should not be construed as a commitment by OAKWORKS Inc OAKWORKS Inc encourages requests for technical specifications and the like documen...

Страница 3: ...21 PT400M Rotating Arm Rests Use 22 PT400M Removable Extension Pad Use 22 Moving the table 23 Dual Locking Casters Use 23 Table Extender Use 24 QuickLock Face Rest Use 24 Adjustable Arm Rest Installa...

Страница 4: ...but a review of the following Safety Instructions is important for the safety of the operator and patient The healthcare professional should read and understand this entire manual before use with a p...

Страница 5: ...furnishing is used near children or disabled persons WARNING To reduce the risk of burns fire electric shock or injury to persons 1 Unplug this furnishing from the electrical outlet before cleaning 2...

Страница 6: ...ery Terra Touch Table Capacity 550 lbs 250 kg patient and accessories Table Weight 170 lbs 70 kg Widths 29 74 cm or 31 79 cm OPTIONS ACCESSORIES Dual Locking Casters QuickLock Face Rest 2 Button Hand...

Страница 7: ...able Voltage Options 120V 60Hz or 230V 50Hz Table Weight 170 lbs 70 kg Table Capacity 550 lbs 250 kg patient and accessories Widths 29 74 cm or 31 79 cm OPTIONS ACCESSORIES Dual Locking Casters QuickL...

Страница 8: ...tient and accessories Upholstery Terra Touch Widths 29 74 cm or 31 79 cm Table Weight 202 lbs 92 kg Length 73 185 cm Padding 4 10 cm Comfort Foam OPTIONS ACCESSORIES Dual Locking Casters QuickLock Fac...

Страница 9: ...SPECIFICATIONS Height Range Powered 16 34 40 86 cm Foot Control Height Motion Table Voltage Options 120V 60Hz or 230V 50Hz Table Capacity 550 lbs 250 kg patient and accessories Widths 27 69 cm or 29...

Страница 10: ...n 1 Powered 16 34 40 86 cm Height Range Motion 2 Manual 0 90 Fowler Backrest Foot Control Height Motion Table Voltage Options 120V 60Hz or 230V 50Hz Table Capacity 550 lbs 250 kg patient and accessori...

Страница 11: ...RD SPECIFICATIONS Motion 1 Powered 16 34 40 86 cm Height Range Motion 2 Manual 55 to 40 Articulating Head Rest Foot Control Height Motion Table Voltage Options 120V 60Hz or 230V 50Hz Table Capacity 55...

Страница 12: ...ATIONS Motion 1 Powered 16 34 40 86 cm Height Range Motion 2 Manual 40 to 90 Articulating Head Rest Foot Control Height Motion Table Voltage Options 120V 60Hz or 230V 50Hz Table Capacity 550 lbs 250 k...

Страница 13: ...16 34 40 86 cm Height Range Motion 3 Manual 40 to 90 Articulating Head Rest Motion 2 Manual 0 90 Fowler Backrest Foot Control Height Motion Padding 1 75 4 4 cm Firm Response OR 2 5 6 4 cm Comfort Foa...

Страница 14: ...CIFICATIONS Motion 1 Powered 17 34 43 86 cm Height Range Motion 3 Manual 0 82 Fowler Backrest Motion 2 Powered 0 to 26 Center Break Motion 4 Manual 47 to 92 Articulating Head Rest Padding 1 75 4 4 cm...

Страница 15: ...tion 3 Manual 0 82 Foot Section Motion 2 Powered 0 to 15 Center Break Foot Control All powered motions Padding 1 75 4 4 cm Firm Response OR 2 5 6 4 cm Comfort Foam OR 4 10 cm Comfort Foam Widths 29 5...

Страница 16: ...eight Range Motion 3 Manual 10 to 90 Articulating Casting Section Motion 2 Manual 0 90 Fowler Backrest Padding 1 75 4 4 cm Firm Response OR 2 5 6 4 cm Comfort Foam Foot Control Height Motion Widths 31...

Страница 17: ...is equipped with a cord having an equipment grounding conductor and a grounding pin The pin must be plugged into an appropriate outlet that is prop erly installed and grounded in accordance with all l...

Страница 18: ...ure the self locking molded rubber feet are flat side down to ensure safety and stability The tables offer height positioning with electronic ease Operate the Foot control and Optional Hand Control as...

Страница 19: ...ubber feet are flat side down to ensure safety and stability The Oakworks PT400 and PT400M tables offer height and center break positioning with electronic ease Operate the Foot control as shown below...

Страница 20: ...e the self locking molded rubber feet are flat side down to ensure safety and stability The Oakworks PT400 and PT400M tables offer height and center break positioning with electronic ease Operate the...

Страница 21: ...krest top is not designed for storage DO NOT use this area for holding anything Damage can occur to the table The Oakworks PX300 tables offer height backrest and footrest positioning with electronic e...

Страница 22: ...the backrest top is not designed for storage Do not use this area for holding anything Damage can occur to the table The Oakworks PX300 tables offer height backrest and footrest positioning with elect...

Страница 23: ...and push the back rest down TO RAISE THE BACK REST Raise the back rest by pressing the lever under the head section and lifting up to the desired height It is recommended that clients take some of th...

Страница 24: ...ck into place automatically TO LOWER THE HEAD REST Twist and hold the knob under the head rest and push the head rest down Release the knob and the head rest will stay in place TO LOWER SIDE RAILS Pus...

Страница 25: ...e Rest platform dowels into the Accessory Mounting Plate that is attached to the table Adjust the Face Rest and Pad as needed Extension Pad Used as a Lowered Arm Rest Extension Pad Used as a Table Ext...

Страница 26: ...ble top to protect the surface from any debris from the bottom of your foot control Two people are required to safely move the table Grasp the table frame securely at the end with the molded rubber fe...

Страница 27: ...when not in use Adjustments are made easily by loosening the cam locks adjusting for height and angle and then locking the cam locks into the desired position Important Safety Note Maximum Distance f...

Страница 28: ...rm rest at a 60 angle to the backrest 2 Push end all the way into the hole and drop the arm rest into the horizontal position Pull outward to make sure the arm rest is secure TO LEVEL THE ARM RESTS Th...

Страница 29: ...cquer plated metals 2 Clorox Hydrogen Peroxide Disinfectant EPA reg 67619 24 corrosion of metals deterioration of upholstery and wood lacquer leaves a hard to remove residue 3 Virox Accel TB EPA reg 7...

Страница 30: ...ain wet for the disinfectant manufacturer s recommended contact time 4 Throw the used wipe s away and allow the table to dry INSPECTIONS RECOMMENDED REGULAR INSPECTIONS monthly or local standard Check...

Страница 31: ...4 2013 Order 654321 Notes Sample Product Label MODEL NUMBER DESCRIPTION P X E X F T X X X X X X A C T T V N F6 Fabric TT TerraTouch Grommet VN Vanilla BK Black Options May be in any order EU Europe F6...

Страница 32: ...he model number and serial number are located on the underside of the foot section Model Number Serial Number 16796025 PXSLA3311873ACTTVN Ser PXR563146 US G2 30 x 22 38 x 72 3M TT 2S TTSKYBLUE 01 04 2...

Страница 33: ...t Service 120 VAC 15 amp 60 Hz 230 VAC 10 amp 50 60 Hz 100 VAC 15 amp 50 Hz Current Draw 2 7 amps 1 5 amps 3 3 amps Maximum Momentary Current Consumption 9 0 amps 5 0 amps 11 0 amps Voltage Output to...

Страница 34: ...netic environment in which radiated RF disturbances are controlled the customer or the user of the table can help prevent electromagnetic interference by maintaining a minimum distance between portabl...

Страница 35: ...ial mode 2 kV common mode 1 kV differential mode 2 kV common mode Mains power quality should be that of a typical com mercial or hospital environ ment Voltage dips short inter ruptions and voltage var...

Страница 36: ...RF transmitters as deter mined by an electromagnetic site survey ashould be less than the compliance level in each frequency range b Interference may occur in the vicinity of equipment marked with the...

Страница 37: ...THIS PAGE IS INTENTIONALLY LEFT BLANK 34...

Страница 38: ...THIS PAGE IS INTENTIONALLY LEFT BLANK 35...

Страница 39: ...THIS PAGE IS INTENTIONALLY LEFT BLANK 36...

Страница 40: ...New Freedom PA 17349 Phone 717 235 6807 FAX 717 235 6798 www oakworksmed com made in the USA with US imported parts 3034177 CONFORMS TO ANSI AAMI STD ES60601 1 IEC STD 60601 1 3RD EDITION IEC STD 606...

Отзывы: