background image

and has not been the result of abuse or misuse within 
the designated period, please return the item freight 

 

pre-paid and correction will be made without charge. 
Eutech Instruments will determine if the product problem 
is due to deviations or customer misuse. Out of warranty 
products will be repaired on a charged basis. Expired RDO 
caps are not eligible for warranty repair or replacement. 
Authorization must be obtained from our Customer Service 
Department or authorized distributor before returning 
items for any reason. A “Return Goods Authorization” (RGA) 
form is available through our authorized distributors. 

 

NOTE: Eutech Instruments Pte Ltd /Oakton Instruments 
reserve the right to make improvements in design, 
construction, and appearance of products without notice.

4. Slide and press the RDO cap onto the RDO sensor 

until the cap is flush with the sensor body. 

See D

Note: 

Do not twist the RDO cap. Once the cap is installed, 

it should not be removed from the RDO sensor unless a 
new cap needs to be installed or troubleshooting needs 
to be performed. 

5.  Connect the RDO sensor to the 9 pin miniDIN input on 

the meter. 

See E

.

RDO Sensor Storage

Store the RDO sensor in the optional calibration chamber, 
making sure to wet the sponge with distilled water, or store 
the sensor in a beaker with distilled water. 

See F

.

Warranty / Return of Items

The sensor body is supplied with a warranty against 
significant deviations in material and workmanship for a 
period of 36 months from date of purchase (12 month 
warranty on RDO cap). If repair or adjustment is necessary 

RDO Optical Dissolved Oxygen Sensor 

Operation Instructions 

Part of Thermo Fisher Scientific

English

 

RDO® Sensor Preparation

Important Note:

 The RDO sensor has an internal clock 

that counts down the 365 day lifespan of a new RDO cap.  
The countdown begins when the RDO cap is installed on 
the RDO sensor, the RDO sensor is connected to the meter 
and the first measurement is taken. The 365 day countdown 
cannot be reset or changed once the first measurement  
is taken. Do not touch the bottom of the RDO cap, optical 
window or spring contacts. Do not immerse the RDO 

 

probe in a solution unless the RDO cap is properly installed 
on the probe.

1.  Remove the protective shipping cap from the end of the 

RDO sensor. 

See A

.

2.  Lubricate the two O-rings on the RDO sensor with a thin 

film of silicone grease. 

See B

3.  Align the arrow on the RDO cap with the arrow on the 

RDO sensor. 

See C

.

Temperature Sensor

Sensor de Temperatura
Temperaturfühler
Sonde de température
Sensore di Temperatura

Thread Ring

Aro de Rosca
Einschraubring
Bague
Anello filettato

Spring Contacts

Contactos Resortes
Federkontakte
Ressort de contact
Contatti a molla

Optical Window

Ventana Optica
Optisches Fenster
Fenêtre optique
Finestra Ottica

O-rings

O-rings
O- Ringe
Joints toriques
O-ring

RDO Cap

Capsula RDO
RDO- Modul
Tête RDO
Cappuccio RDO

Aro de Rosca
Einschraubring
Bague
Anello filettato

Spring Contacts

Contactos Resortes
Federkontakte
Ressort de contact
Contatti a molla

Optical Window

Ventana Optica
Optisches Fenster
Fenêtre optique
Finestra Ottica

es

Optional Weight / Guard

Opcional Peso / Guardia
Optional Gewicht / Schutz
Option Poids / Garde
Opzionale Peso / Guard

RDO Cap

Capsula RDO
RDO- Modul
Tête RDO
Cappuccio RDO

A

B

C

D

E

F

O
O
O
O

Instrucciones de funcionamiento / Mode d’emploi /  
Betriebsanleitung / Istruzioni per l’uso

Calibration Chamber

Cámara de Calibración
Chambre d’étalonnage
Kalibrierung Kammer
Camera Calibration

Español

 

Preparacion de Sensor RDO 

Nota Importante:

 El Sensor RDO tiene un reloj interno que 

lleva una cuenta regresiva partiendo de 365 dias. Este es 
el periodo de vida de una nueva Capsula RDO. La cuenta 
regresiva comienza cuando la Capsula RDO se instala al 
Sensor RDO y el Sensor RDO se conecta al equipo y se toma 
la primera lectura. La cuenta regresiva de 365 dias no se 
puede cambiar ni resetear una vez que se realiza la primera 
lectura. No toque la parte inferior del tapón óptico, ventana 
óptica o contactos de resorte. No sumerja la sonda RDO  
en una solución a menos que el tapón óptico está 

 

instalado correctamente.

1.  Remueva la capa protectora del sensor RDO. 

Ver A

.

2.  Lubricar los dos O-rings en el sensor RDO con una capa 

muy delgada de grasa de silicone. 

Ver B

.

3.  Alinear la flecha de la Capsula RDO con la flecha en el 

Sensor RDO. 

Ver C

.

4.  Deslize y presione la Capsula RDO al Sensor RDO hasta que 

la capsula quede emparejada al cuerpo del sensor. 

Ver D

Nota: 

No enrosque la Capsula RDO. Una vez que la 

capsula se instala, la misma no debe removerse del 
Sensor RDO al menos que una nueva capsula se vaya 
a instalar o sea necesario resolver un problema en el 
funcionamiento del Sensor. 

5.  Conecte el Sensor RDO al conector de 9 pines miniDIN 

del equipo. 

Ver E

.

Almacenaje Del Sensor RDO

Almacene el Sensor RDO en la manga de calibracion. 
Asegurese de humedecer la esponja de la manga con agua 
destilada o almacene el Sensor en un beaker con agua 
destilada. 

Ver F

.

Garantía / Vuelta De Artículos

El cuerpo del sensor se suministra con una garantía contra 
las desviaciones significativas en los materiales y mano 

de obra por un período de 36 meses a partir de la fecha 
de compra (garantía de 12 meses en el tapón óptico). 
Si es necesario reparar o ajuste y no ha sido el resultado 
de abuso o mal uso en el plazo establecido, por favor 
devuelva el artículo flete pagado y la corrección se hará 
sin costo alguno. Eutech Instrumentos determinará si 
el problema del producto se debe a desviaciones o mal 
uso de los clientes. Productos fuera de garantía serán 
reparados de forma acusada. Tapas RDO caducados no son 
elegibles para su reparación o sustitución. Se debe obtener 
autorización de nuestro departamento de servicio al cliente 
o distribuidor autorizado antes de volver artículos por 
cualquier razón. Un formulario de “Autorización de Retorno 
de Mercancías” (RGA) está disponible a través de nuestros 
distribuidores autorizados. NOTA: Instrumentos Eutech 
Pte Ltd / Instrumentos Oakton reservamos el derecho de 
hacer mejoras en el diseño, construcción y aspecto de los 
productos sin previo aviso.

www.

GlobalTestSupply

.com

Find Quality Products Online at:

[email protected]

Отзывы: