background image

3_ Remove the cover and replace the 

battery with the positive side facing 

up.

NOTE: 

Be careful not to damage or lose

the o-ring gasket on the cover.

4_ Use a coin to twist the coverback 

into place.

SWITCHING OFF THE SENSOR

After 3 minutes of inactivity, all sensors

automatically power off to conserve the

battery.

For more information about optional 

accessories, go to www.o-synce.com. You

can also contact your o-synce dealer to

purchase accessories.

TECHNICAL FEATURES

Physical size:

65 x 38 x 11 mm

Weight:

25 g

Water Resistance:

10 m

Transmission range:

Approximately 3 m (9.8 ft)

Battery: 

User-replaceable CR2032 (3 volts)

Battery Life:

Approximately 3 years (1 hour per day)

HEART2feel free/X SOFT BELT

The chest strap must be positioned

around your chest. when correctly

placed, it sends heart rate informa-

tion to the watch. Located on the

wrist, the watch displays the heart

rate and provides various extra infor-

mation (target zone, intensity of exer-

cises) to manage and optimize your

fitness and training. The soft belt will

be connected with to clips at the

sensor case. The rubber areas have

to be placed on the skin (see photo

below)

USING THE 

HEART2feel free/X SOFT BELT

The Heart2feel free sensor is using an

analog  RF communication, so no need

for any pairing. You can use it like des-

cribed in the manual of the matching

product (MIXfree & MACRO free)

The Heart2feel X sensor has to be pai-

red like described in the manual for

MIXpro & MACRO X – settings - pairing

1_ Connect the soft belt with the sensor

on one side. Push one bottom of the 

heart rate sensor on the strap.  

2_ Wet both sensors on the back (rub-

ber area) of the heart rate monitor to

create a strong connection between 

your chest and the transmitter 

(for extremely dry skin use some 

special gel)

3_ Wrap the strap around your chest 

and attach it to the other side of the 

heart rate monitor.

NOTE: 

The o-synce logo should be

right-side up.

4_ Bring the o-synce product you want 

to use within range (3 m) of the 

heart rate monitor. 

5_ follow the instruction in user guide to

connect and pair!

OP

EN

CR2032

3V

+

NOTE:

If or heart rate data does not

appear or if you have erratic heart rate

data, you may have to tighten the strap

on your chest or warm up for 5–10 mi-

nutes. If the problem persists, you may

have to pair the sensors.

Reapply moisture to the sensors. Use

water, saliva, or electrode gel. Clean the

sensors. Dirt and sweat residue on the

sensor can interfere with heart rate si-

gnals.

Synthetic fabrics that rub or flap against

the heart rate monitor can create static

electricity that interferes with heart rate

signals.

NOTE:

In cold conditions, wear appro-

priate clothing to keep the heart rate

monitor near your body temperature.

Accuracy may be degraded by poor

sensor contact, electrical interference

and receiver distance from transmitter.

Strong electromagnetic fields and some

2.4 GHz wireless sensors can interfere

with your heart rate monitor. Sources of

interference may include very high vol-

tage power lines, electric motors, micro-

wave ovens, 2.4 GHz cordless phones,

and wireless LAN access points. After

you move away from the source of inter-

ference, your heart rate data should re-

turn to normal.

NOTE:

Stay 10 m away from other 

ANT sensors while pairing. Bring the 

o-synce product within range (3 m) of

the heart rate monitor while pairing. If

the problem persists, replace the bat-

tery. 

TO REPLACE THE BATTERY

1_ Locate the circular battery cover on 

the back of the sensor.

2_ Use a coin to twist the cover coun-

er-clockwise until it is loose enough 

to remove.

HEART2feel