Positioning of Boostbox Units
Boostbox
– Setup and Installation Guide V3.5
Boostbox units are designed to work vertically and can either be free standing* or wall mounted. They should be
located in as open a location as practical, i.e. not completely surrounded by obstructions such as monitors,
printers, etc.
* Metro Boostbox can only be wall mounted.
Free Standing
The larger office (Enterprise) Boostbox includes a small stand which can be attached to the bottom of the unit.
This adds stability and ensures free flow of air through the bottom vents to prevent overheating.
Wall Mounting
The larger office (Enterprise) Boostbox includes 4 rubber spacers which must be fixed to the corners on the
back of unit to ensure a 5mm spacing when wall mounting. When wall mounting, we would also recommend
leaving a 0.5 metre gap between the top of the unit and the ceiling.
The Metro Boostbox unit will typically be installed by our contractors. Where it is to be self installed we will
provide guidance.
Locations to Avoid
In most cases, Boostbox units should not be mounted underneath desks or above false ceilings as this will
greatly reduce their effectiveness and will likely result in a poor user experience. There may be some situations
where this is ok in which case your O2 designer will advise.
Positioning in Relation to Other Operator Boostbox Units / Femtocells
If you have the equivalent of Boostbox from other mobile operators and wish to have them switched on together
then you should keep them a minimum of 2 meters apart. If you can separate them by over 5 metres then this
would be ideal.