NXP Semiconductors
AH1721
SJA1105SMBEVM UM
AH1721
All information provided in this document is subject to legal disclaimers.
© NXP Semiconductors N.V. 2018. All rights reserved.
User Manual
Rev. 1.00
— 16 July 2018
12 of 35
Table 5.
Pinning of the debug connector J10
Meaning/Name
Pin
Pin
Meaning/Name
JTAG_TDI
1
2
GND
JTAG_TDO
3
4
GND
JTAG_TCK
5
6
GND
n.c.
7
8
n.c.
JTAG_RESET (PowerPC Reset)
9
10
JTAG_TMS
VREF (3V3)
11
12
GND
n.c.
13
14
JCOMP (10k pulldown)
4.9 Buttons and switches
Table 6.
Buttons and switches
Name
Meaning/Usage
SW1
Wakeup
– connects the PHYs’ wakeup line with VCC – this is for wakeup/sleep
SW2
Reset button
– controls the uC’s reset input.
SW3,
SW4
General purpose buttons connected to interrupt capable GPIOs
SW3: Button0
SW4: Button1
SW5
Rotary switch with 16 positions
The software can make use of the rotary switch to select a specific board configuration.
The example software project uses the rotary settings in the following way to
enable/disable ethernet and/or CAN operation:
Table 7.
Rotary switch configuration in the example project
Configuration:
Ethernet operation
CAN operation
0
no
no
1
yes
yes
2
yes
no
3
no
yes
4-F
Not used
– see configuration #0
For ethernet operation, the switches and PHYs are initialized and configured with a
simple setup, and the µC periodically sends out a packet on its both ethernet ports
– one
port connected to the switches and another one to the FE port.
For CAN operation the µC periodically tries to send out a CAN telegram, and reports
received telegrams on the serial console.
5. Getting started
The following steps are required to bring the SJA1105SMBEVM into operation:
1. Installation of the software development environment S32DS for Power
Architecture