NXP Semiconductors
UM10858
PN7462 family HW user manual
UM10858
All information provided in this document is subject to legal disclaimers.
© NXP B.V. 2018. All rights reserved.
User manual
COMPANY PUBLIC
Rev. 1.4 — 14 May 2018
314514
171 of 345
Table 209. CLIF_TIMER0_CONFIG_REG register (address 0078h)
* = reset value
Bit
Symbol
Access
Value
Description
31
T0_STOP_ON_T3_E
XPIRED
R/W
0*, 1
T0_STOP_EVENT: If set the timer T0 is stopped when timer
T3 raises its expiration flag.
30
T0_STOP_ON_RX_
STARTED
R/W
0*, 1
T0_STOP_EVENT: If set the timer T0 is stopped when a
data reception begins (1st bit is received).
29
T0_STOP_ON_TX_S
TARTED
R/W
0*, 1
T0_STOP_EVENT: If set the timer T0 is stopped when a
data transmission begins.
28
T0_STOP_ON_RF_
ON_EXT
R/W
0*, 1
T0_STOP_EVENT: If set the timer T0 is stopped when the
external RF field is detected.
27
T0_STOP_ON_RF_O
FF_EXT
R/W
0*, 1
T0_STOP_EVENT: If set the timer T0 is stopped when the
external RF field vanishes.
26
T0_STOP_ON_RF_
ON_INT
R/W
0*,1
T0_STOP_EVENT: If set, the timer T0 is stopped when the
internal RF field is turned on.
25
T0_STOP_ON_RF_
OFF_INT
R/W
0*,1
T0_STOP_EVENT: If set, the timer T0 is stopped when the
internal RF field is turned off.
24
T0_STOP_ON_SIGI
N_ACT
R/W
0*,1
T0_STOP_EVENT: If set, the timer T0 is stopped when an
activity on SigIn is detected.
23:19
RESERVED
R
0
Reserved
18
T0_START_ON_T3_
RUNNING
R/W
0*, 1
T0_START_EVENT: If set, the timer T0 is started when the
timer T3 starts running.
17
T0_START_ON_RX_
STARTED
R/W
0*, 1
T0_START_EVENT: If set, the timer T0 is started when a
data reception begins (1st bit is received).
16
T0_START_ON_RX_
ENDED
R/W
0*, 1
T0_START_EVENT: If set, the timer T0 is started when a
data reception ends.
15
T0_START_ON_TX_
STARTED
R/W
0*, 1
T0_START_EVENT: If set, the timer T0 is started when a
data transmission begins.
14
T0_START_ON_TX_
ENDED
R/W
0*, 1
T0_START_EVENT: If set, the timer T0 is started when a
data transmission ends.
13
T0_START_ON_RF_
ON_EXT
R/W
0*, 1
T0_START_EVENT: If set, the timer T0 is started when the
external RF field is detected.
12
T0_START_ON_RF_
OFF_EXT
R/W
0*, 1
T0_START_EVENT: If set, the timer T0 is started when the
external RF field is not detected any more.
11
T0_START_ON_RF_
ON_INT
R/W
0*, 1
T0_START_EVENT: If set, the timer T0 is started when an
internal RF field is turned on.
10
T0_START_ON_RF_
OFF_INT
R/W
0*, 1
T0_START_EVENT: If set, the timer T0 is started when an
internal RF field is turned off.
9
T0_START_ON_SIG
IN_ACT
R/W
0*, 1
T0_START_EVENT: If set, the timer T0 is started when an
activity on SigIn is detected.
8
T0_START_NOW
D
0*, 1
T0_START_EVENT: If set, the timer T0 is started
immediately.
7:6
RESERVED
R
0
Reserved
5:3
T0_PRESCALE_SEL
R/W
0h-7h
Controls frequency/period of the timer T0 when the prescaler
is activated in T0_MODE_SEL.
000
6.78 MHz counter