Here is an example of Type A Reader RF gate initialization:
HOST
PN544
ADM_CREATE_PIPE
( READER RF GATE A ID = ‘0x13’)
ANY_OPEN_PIPE
ADM
Gate
ADM
Gate
Type A
Reader
Gate
Type A
Reader
Gate
ANY_OK
( PipeID )
ADM
Gate
ADM
Gate
ANY_OK
Type A
Reader
Gate
Type A
Reader
Gate
HOST must save the
PipeID returned by PN544
for the Type A Reader
Gate initialization.
Fig 27. Type A Reader RF Gate initialization
For all the gates with dynamic Pipe ID, the initialization should be performed as follows:
Fig 28. Gate ‘X’ initialization
Note: Only Link management gate & administration gate have a static Pipe ID, all other