WCT1012VLF/WCT1013VLH Consumer MP-A11 (WCT-
15W1CFFPD) V1.0 Wireless Charging Application User’s
Guide, Rev. 1, 05/2019
52
NXP Semiconductors
Coil current
8000 mA
gPROT_Params.wMaxCoilCurrent
Application implemented. If the coil current
exceeds the limit, charging is turned off. The
limit value can be changed by the
FreeMASTER GUI.
Temperature
Max: 60
℃
Hysteresis:
10
℃
gPROT_Params.swTemperatureThres
hold
gPROT_Params.wTemperatureHyst
Application implemented. If the temperature
exceeds the maximum, the WCT library
stops. When the temperature is lower than
the difference between the maximum and
hysteresis, the WCT library starts. The
maximum limit can be changed by the
FreeMASTER GUI. The hysteresis value can
be changed in PROT_Init().
Safe digital ping
200 mA
gPROT_Params.wSafeDigitalPingInpu
tCurrentThreshold
Library implemented. If the input current
sampled at the beginning of the digital ping
exceeds the limit, digital ping stops. The limit
value can be changed in PROT_Init().
FOD
BPP RX:
400 mW
EPP RX:
800 mW
EPP5W RX:
450 mW
gWCT_Params.wBPPLPPowerLossTh
resholdInOperationMode
gWCT_Params.wEPPMPPowerLossT
hresholdInOperationMode
gWCT_Params.wEPPLPPowerLossTh
resholdInOperationMode
Library implemented. If the power loss
exceeds the limit, charging is turned off for 5
minutes. The limit value can be changed by
the FreeMASTER GUI.
9. System bring up
9.1. Ping sequences
When the low-power mode is disabled and no receiver is placed on the charging surface, the ping
sequence is as follows:
The digital ping appears about every 5 seconds and the analog ping appears about every 400 ms. There
are 12 to 13 analog pings between two digital pings.
The following figures show the PWM waveforms of the ping sequence and ping patterns.