Chapter 10: LPC800 State Configurable Timer (SCT)
The current state can be read at any time by reading the STATE register.
To change the current state by software (that is independently of any event occurring), set
the HALT bit and write to the STATE register to change the state value. Writing to the
STATE register is only allowed when the counter is halted (the HALT_L and/or HALT_H
bits are set) and no events can occur.
10.7.11 Configure the SCT without using states
The SCT can be used as standard counter/timer with external capture inputs and match
outputs without using the state logic. To operate the SCT without states, configure the
SCT as follows:
•
Write zero to the STATE register (zero is the default).
•
Write zero to the STATELD and STATEV fields in the EVCTRL registers for each
event.
•
Write 0x1 to the EVn_STATE register of each event. Writing 0x1 enables the event.
In effect, the event is allowed to occur in a single state which never changes while the
counter is running.