TEA1613T resonant power supply control IC
11. Miscellaneous advice and tips
11.1 PCB layout
11.1.1 Grounding
SGND + PGND
must
be connected directly under the IC (in ground plane if possible) to
avoid false signal detection by driver current disturbance (see
).
A star grounding construction provides the lowest risk of mutual converter disturbance or
signal detection disturbance. In this system, the central star point can be chosen at the
V
BOOST
capacitor ground.
Large currents should be avoided on grounding tracks that are intended for signal
measurement.
11.1.2 Large current loops
Fig 52. Ground structure and current loops in an application with PFC
001aal474
TEA1613
mains
voltage
PFC
V
boost
HBC
PGND
GATELS