22
3.
4.
Pull the unit out until braking is felt. For safety purposes, the locking mechanism will not
allow a complete removal of the unit at this stage.
Pulling the Unit Outwards
Press on the locking spring (appears in red in the figure below) on both sides simultaneously,
and continue pulling the unit towards you until it is fully removed.
Locking Mechanism
Cable Installation
All cables can be inserted or removed with the unit powered on.
To insert a cable, press the connector into the port receptacle until the connector is firmly seated.
The LED indicator, corresponding to each data port, will light when the physical connection is
established. When a logical connection is made, the relevant port LED will turn on.
To remove a cable, disengage the locks and slowly pull the connector away from the port
receptacle. The LED indicator for that port will turn off when the cable is unseated.
For full cabling guidelines, please refer to the
Mellanox Cable Management Guidelines and FAQ
.
For more information about port LEDs, refer to
Cable Orientation
Do not force the cable into the cage with more than 40 newtons / 9.0 pounds / 4kg force.
Greater insertion force may cause damage to the cable or to the cage.