Cooling

7

4.4  Power Supply

The system has a 150 W open frame AC power supply with wide range AC input and 12 V DC output.

The DC output is connected directly to the power management circuitry on the backplane.

The power input is provided by an AC mains/line module with IEC 320-C14 connector, integrated 
mains/line fuses, line filter and a mains/line switch.

Fuse value is T2AH250V.

Figure 5: AC Input

Table 1:  Data AC Power Supply

e

Hazardous voltage!

Parts of the power supply may be exposed with hazardous voltage.

Always remove mains/line connector before carry out any assembly work.

Caution!

The unit is designed in accordance with protection class 1! It must therefore be operated with protec-
tive earth/GND connection. Use only a three conductor AC power cable with a protective earth

conductor that meets the IEC safety standards!

Caution!

There is a ground terminal at the right side. This ground terminal is only for equipotential bonding. 
Grounding is achieved through the protective earth conductor of the power cable!

1

AC Input

3

Equipotential bonding

2

Mains switch

4

Fuse holder

Input voltage

100 - 240 VAC

Mains Frequency

50 / 60 Hz

Output (max.)

150 W

Output voltage

12 V DC

Output voltage ripple and noise

120 mVpp

Operating Temperature

-5° C - +55° C

Содержание SCHROFF 11850-016

Страница 1: ...User Manual 1 U MTCA Shelf Product Number 11850 016 Doc No 63972 350_R1 0 February 2016 ...

Страница 2: ...efully compiled and checked supported by certified Quality Management System to EN ISO 9001 2000 The company cannot accept any liability for errors or misprints The company reserves the right to amendments of technical specifications due to further development and improvement of products Copyright 2016 All rights and technical modifications reserved ...

Страница 3: ...plane 4 3 1 Backplane Topology 4 3 2 Fabric Interface 5 3 2 1 Common Options 5 3 2 2 Fat Pipe 5 3 2 3 Extended Fat Pipe 5 3 3 Intelligent Platform Management Bus IPMB 5 3 3 1 IPMB L 5 3 4 Power Management 5 4 Cooling 6 4 1 Air Filter 6 4 2 Air filter swap 6 4 3 Cooling 6 4 4 Power Supply 7 5 EMCH Embedded MicroTCA Carrier Hub 8 5 1 Front Panel and LEDs 9 5 2 Comand Line Interface CLI 10 5 2 1 COM ...

Страница 4: ...11850 016 II R1 0 February 2016 ...

Страница 5: ...m 1 3 References and Architecture Specifications PICMG MTCA 0 Specification www picmg com PICMG AMC Base Specification www picmg com Hazardous voltage This is the electrical hazard symbol It indicates that there are dangerous voltages inside the Shelf Caution This is the user caution symbol It indicates a condition where damage of the equipment or injury of the service personnel could occur To red...

Страница 6: ... MicroTCA Backplane EMCH Embedded MicroTCA Carrier Hub with basic MicroTCA functionality for switching and managing two AMCs Advanced Mezzanine Cards Power management controller on the backplane Active cooling through 4 fans for cooling the AMC modules 1 fan for cooling the power supply Easy removable air inlet filter Integrated 150 W AC Power Supply with wide range AC input and 12 V DC output AC ...

Страница 7: ...rap Terminal 4 mm banana jack is located left to the card cage 1 ESD Wrist Strap Terminal 5 EMCH interfaces 2 2 HP Filler panel 6 Ground Terminal Equipotential bonding 3 AC input 7 PSU 4 Mains line switch 8 EMCH Danger of electrostatic discharge The Shelf contains static sensitive devices To prevent static damage you must wear an ESD wrist strap ...

Страница 8: ...ocks FCLKA AMC 1 1 connection Clocks TCLKB AMC Output Clocks TCLKC AMC Clocks TCLKD AMC Output Clocks TCLKA AMC IPMB_L DC DC Converter 3 3V HotSwap AMC Port 2 SATA AMC Port 3 SATA MCH AMC Port 4 7 FAT PIPE Port 0 Port 1 Fabric 2 A 1000Base BX Common Options Port 2 Port 3 A 4 Port 4 7 A B B C C D D FAN1 FAN2 FAN3 FAN4 FAN5 12V FAN _Control PPWR_2 PPWR_1 PPWR MP_2 PRESENT_1 MP I C Carrier Number 12V...

Страница 9: ...ween both AMC slots 3 2 3 Extended Fat Pipe AMC slots Port 8 11 are direct slot to slot connections between both AMC slots 3 3 Intelligent Platform Management Bus IPMB MicroTCA uses an Intelligent Platform Management Bus IPMB for management communications 3 3 1 IPMB L Radial IPMB from MCH to both AMCs 3 4 Power Management The integrated power management circuitry on the backplane provides 12 V pay...

Страница 10: ...e pulled out after removing the top cover The filter meets the requirements of the Telcordia Technologies Generic Requirements GR 78 CORE specification 4 3 Cooling Figure 4 Airflow The MicroTCA Shelf is equipped with four 12 VDC fans for cooling the AMC modules and one 12 VDC fan for cooling the power supply The fans are controlled as a group by the EMCH e 1 Air Filter ...

Страница 11: ...age Always remove mains line connector before carry out any assembly work Caution The unit is designed in accordance with protection class 1 It must therefore be operated with protec tive earth GND connection Use only a three conductor AC power cable with a protective earth conductor that meets the IEC safety standards Caution There is a ground terminal at the right side This ground terminal is on...

Страница 12: ...itors and verifies local sensor data of the chassis and installed FRU devices and supplies MicroTCA power and cooling concepts by accessing the chassis integrated power supply and fan coolers Remote administration can be done locally over the CLI Command Line Interface served by the front USB port Figure 6 EMMC Block Diagram Microcontroller 1000Base BX 2 MII 1000Base BX 1 1000Base T Uplink IPMB L ...

Страница 13: ...ill be put on OK FAIL 1 2 AMC Type Function LED AMC1 Blink Short Reading FRU information M1 Blink Slow Waiting for HS Handle being closed M1 ON FRU operating state M4 OFF No Module installed LED AMC2 Blink Short Reading FRU information M1 Blink Slow Waiting for HS Handle being closed M1 ON FRU operating state M4 OFF No Module installed LED OK Blink Slow Blink Short Test Mode ON Normal operating st...

Страница 14: ...river automatically by the windows update may take up to a few minutes Table 4 CLI Commands Baudrate 115200 Data 8 bit Parity None Stop 1 bit Flow control None COM The devices COM address defined by host Command Parameter Description bi Board Information Prints the vital product information record i e Serial num ber Hardware revision and release codes ip ip netmask gateway IP configuration Configu...

Страница 15: ... have changed slightly and will prompt you to enter a password By default the password is nat To leave the bootloader without touching anything just click on Leave Bootloader By clicking on submint the upload page should open Now select a proper firmware image with the file extension srec Click upload to flash the image into the device memory NOTE The upload process will take a few seconds please ...

Страница 16: ...m Depth approx 302 mm Weight Weight completely assembled approx 2 7 Kg Power Supply Input Voltage 100 VAC to 240 VAC Mains Frequency 50 Hz to 60 Hz Input Current 1 2 A at 100 VAC 0 5 A at 240 VAC Input Fuse 2x T2AH250V Environmental Ambient temperature 5 C 45 C long term Ambient temperature 5 C 55 C short term Humidity 5 85 non condensing ...

Страница 17: ......

Страница 18: ...Schroff GmbH Langenalber Str 96 100 75334 Straubenhardt Germany Tel 49 7082 794 0 Fax 49 7082 794 200 Doc No 63972 350_R1 0 ...

Отзывы: