3  Installation

3.1  General Installation Guidelines

3.1.1  Unpacking

Consider the following when unpacking and storing the system:

Leave the system packed until it is needed for immediate installation.

After unpacking the system, save and store the packaging material in case 

the system must be returned.

If the packaging is damaged and possible system damage is present, report to 
the shipper and analyze the damage.

3.1.2  Ensuring Proper Airflow  

Maintain ambient airflow to ensure normal operation. If the airflow is blocked 
or restricted, or if the intake air is too warm, an over temperature condition 
can occur. 

Ensure that cables from other equipment do not obstruct the airflow through 
the systems. 

Use filler panels to cover all empty chassis slots. The filler panel should 
include an airflow baffle that extends to backplane. The filler panel prevents 
fan air from escaping out of the front of an open slot.

Caution!

When opening the shipping carton, use caution to avoid damaging the system.

Содержание CPCI

Страница 1: ...CPCI System Subrack 3 U User s Manual Product No 24579 031 December 16 2010 Doc No 63972 255_R1 1...

Страница 2: ...ISO 9001 2000 The company cannot accept any liability for errors or misprints The company reserves the right to amendments of technical specifications due to further development and improvement of pro...

Страница 3: ...ions 3 2 2 System Overview 3 2 3 Subrack 4 2 4 CPCI Backplane 4 2 5 Power Supply 5 2 5 1 ATX Power Supply 5 2 5 2 Grounding Earthing 5 2 6 Cooling 6 3 Installation 7 3 1 General Installation Guideline...

Страница 4: ...CPCI System Subrack 3 U 24579 031 www schroff biz II R1 0 December 16 2010...

Страница 5: ...and alone functionality additional elements are required An operational system is achieved only by way of appropriate CPCI boards The completion and final testing of the units have been carried out or...

Страница 6: ...ons to avoid accidents before starting to work with parts that carry dangerous voltages Caution This is the user caution symbol It indicates a condition where damage of the equipment or injury of the...

Страница 7: ...older for an optional slim line DVD drive Drive holder for an optional 3 5 HDD 2 1 References and Architecture Specifications User Manual CPCI Backplanes Order no 73972 101 User Guide Schroff CPCI Bac...

Страница 8: ...des CompactPCI bus 32 bit PICMG2 0 R 3 0 with System Slot right System slot expandable from 4 HP to 8 HP Rear I O on P2 V I O 5 V adjustable to 3 3 V Bridge connector for secondary Backplane Applicabl...

Страница 9: ...oltage 90 264 VAC active PFC Input frequency 47 63 Hz Input current 5 A 115 V 2 5 A 230 V Output max 5 V 35 A 3 3 V 28 A 12 V 22 A 12 V 0 8 A Output min 5 V 0 5 A 3 3 V 0 A 12 V 0 5 A 12 V 0 0 A Inrus...

Страница 10: ...ower supply are cooled by natural air convection through the perforated base cover and top cover The operating temperature is from 0 C to 50 C Figure 2 Airflow Caution To maintain proper airflow all o...

Страница 11: ...amage is present report to the shipper and analyze the damage 3 1 2 Ensuring Proper Airflow Maintain ambient airflow to ensure normal operation If the airflow is blocked or restricted or if the intake...

Страница 12: ...iest system at the bottom avoid uneven mechanical loading of the rack 3 3 Initial Operation Ensure that the system has not been damaged during transport storage or assembly Check the Protective Earth...

Страница 13: ...ns and therefore a CE marking is not required However when CPCI cards are assembled according to specification the systems fulfill the requirements in accordance with EMC Directive 2004 108 EG and Low...

Страница 14: ...nnector and mains line switch 4 voltages 3 3 V 28 A 5 V 35 A 12 V 22 A 12 V 0 8 A 1 Complete AC DC cabling 1 Drive holder for a slim line DVD drive 1 Drive holder with front panel 3 U 4 HP for a 3 5 H...

Страница 15: ...60 Hz Power input up to 300 W Cooling Natural Convection Ambient Temperature Operation 0 C to 50 C Storage 40 C to 85 C Humidity Admissible humidity 30 to 80 non condensing EMC fulfils requirements fo...

Страница 16: ...CPCI System Subrack 3 U Dimensions 24579 031 www schroff biz 12 R1 1 December 16 2010 6 Dimensions Figure 3 Dimensions...

Страница 17: ......

Страница 18: ...SCHROFF GMBH www schroff biz Langenalberstr 96 100 Tel 49 0 7082 794 0 Fax 49 0 7082 794 200 D 75334 Straubenhardt...

Отзывы: