background image

UNLESS NOTED, DIMENSIONS ARE IN 

MILLIMETERS & TOLERANCES ARE:

ENGINEER:

SIZE:

REV.

DRAWN BY:

    X.

X.X

X.XX

X.X

X.XX

1      MM

0.5   MM

0.20 MM

0.3   MM

0.10 MM

X

1

X.X   0.5

INTERPRET PER ASME Y14.5M-1994

BRACKETED DIMENSIONS ARE IN 

INCHES FOR REFERENCE ONLY

THRID ANGLE PROJECTION

LRF

APPROVED BY:

PART NO:

TITLE:

PROJECT:

A3

THIS DRAWING AND SPECIFICATIONS HEREIN ARE THE PROPERTY OF CIS 

GLOBAL AND SHALL NOT BE COPIED, REPRODUCED OR USED IN WHOLE OR IN 

PART, AS THE BASIS FOR THE MANUFACTURE OR SALE OF ITEMS WITHOUT 

WRITTEN PERMISSION FROM CIS GLOBAL. THIS DRAWING IS BASED UPON 

LATEST AVAILABLE INFORMATION AND IS SUBJECT TO CHANGE WITHOUT NOTICE

E1

2022/05/10

RB03

2

4**

*

*_DA

Rack

Power

SHEET

OF 3

SCALE:N/A

ECN/ECO REV.

DESCRIPTION

DATE

APPROVED

REVISIONS

E1

INITIAL DRAFT REVIEW

2022/05/10

LRF

$

$

%

%

&

&

'

'

(

(

)

)

*

*

+

+

-

-

.

.

/

/

0

0

 Advantage Series 

Basic

(DEFAULT) TOP FEED = 0

BOTTOM FEED = 2

(DEFAULT) 

3m  [10'] 

  = 0

(DEFAULT) BLACK  = 0

RED  = R

GREEN  = G

MODEL IS SHOWN IN DEFAULT CONFIGURATION. FOR 
OPTIONAL CONFIGURATIONS, USE ITEM  IDENTIFIER 

CODE IN PLACE OF EACH ASTERISK. ORDERABLE 

BASED ON FORMAT:  R

B0

32

4

* * * *

DO NOT INCLUDE TRAILING ZEROS IN * * * * SUFFIX

OPTIONS LISTED ON THIS ROW ARE NON STANDARD, 

CONTACT SALES FOR ADDITIONAL INFORMATION

R

B

 

0324

0.5m [1.6']  = A

1.5m [4.9']  = B

2.5m [8.2']  = C

1.2m [4']  = G
1.8m [6']  = F

(DEFAULT) 

L6

3

0P = 0 

BLUE  = B

WHITE  = W

YELLOW  =  Y

IDENTIFICATION TABLE

INPUT PLUG

CHASSIS COLOR

CORD OPTION

ORIEN

*

TATION

ORANGE  = A

1m [3.2']  = 1 

2m [6.6']  = 2 

*

*

*

NOTES

:

NATIONAL, STATE

1.

INSTALLATION SHALL COMPLY WITH ALL APPLICABLE 

AND LOCAL CODES.

2.

3.

PRIMARY DIMENSIONS ARE IN MILLIMETERS. SECONDARY DIMENSIONS

ARE IN [INCHES]

UNIVERSAL MOUNTING BRACKET IS AN ALTERNATIVE MOUNTING
METHOD TO THE TOOLLESS MOUNT FOR 3RD PARTY ENCLOSURES.
BRACKET IS PROVIDED WITH THE UNIT.

4.

DETAILED INSTALLATION INSTRUCTIONS CAN BE FOUND IN THE QUICK
START GUIDE

5.

CONNECT EXTERNAL EARTH GROUND TO THE 10-32 SIZE THREADED NUT

6.

7.

SEE PRODUCT DOCUMENTATION FOR FURTHER INFORMATION
INPUT PLUG CONFIGURATION (SEE IDENTIFICATION TABLE) FOR DUAL-
RATED UNITS, NEMA PLUGS ARE NAM RATED ONLY AND CAPTIVE AUS/NZ
PLUGS ARE EMEA RATED ONLY

MAX OPERATING
ELEVATION, ABOVE MSL

HUMIDITY
(OPERATING/STORAGE)

METERING

ACCURACY

5-90% RH / 5-95% RH;

NON-CONDENSING

VOLTAGE(V), CURRENT(A), APPARENT

POWER(kVA), REAL POWER(kW),
POWER FACTOR, ENERGY(kWh)

3000M(9840FT)

RoHS COMPLIANT

COMPLIANCE

SAFETY&ENVIRONMENTAL

METERING ATTRIBUTES

FEATURES

INPUT POWER CORD:

METERED COMPONENTS
REMOTE OUTLET SWITCHING

ENVIRONMENTAL CONDITIONS

OPERATING TEMPERATURE
STORAGE TEMPERATURE

INPUT PLUG:

RATED POWER:

INPUT PHASE:

BREAKER QTY & TYPE:

INPUT CURRENT:

INPUT VOLTAGE:

OUTLET QTY & TYPE:

ORIENTATION:

UNIT TYPE:

TECHNICAL SPECIFICATIONS

BASIC

VERTICAL, MID

(20) C13, (4) C19

200-240VAC

30A (24A DERATED)

(2) 20A, 

DOUBLE

-POLE

 

SINGLE

-PHASE

5.0kVA

SEE NOTE 7

SEE IDENTIFICATION TABLE

+-1% TO ISO/ IEC 62052-21

INPUT(PHASE), CIRCUIT BREAKERS

YES

-5 TO 60 C (23 TO 140 F)

-20 TO 60 C (-4 TO 140 F)

52.0

[2.05'']

53.0

[2.09'']

REAR VIEW

(2) PL Ø18.4

[.72'']

65.5

1244.0

(2) PL 24.0

[2.58'']

[.94'']

65.5

1244.0

[58.66'']

[2.58'']

1490

(2) PL 24.0

[.94'']

SIDE

 VIEW

[48.98'']

(4) PL 32.0

[1.26'']

B1

[

BLUE

 ]

B2

[ LIGHT GRAY ]

FRONT VIEW

BOTTOM VIEW

[48.98'']

TOOLESS MOUNTING BUTTON 

LOCATIONS (12) PL

INPUT CORD

LENGTH SEE

 IDENTIFICATION

 TABLE

Rack

Power

Отзывы: