PROGRAM START

Quickstart:                    

Navigation:     SELECTION           back ( <-  )     or next   ( -> )

Language selection

Select your language from the language menu:
EN; DE; NL; DA; FR; IT; SV; NO; FI; RU; CZ; PL; SK; LT
next  ( -> )

Checking sensor connection

The unit is automatically executing a connection check of the sensors 

1

 and 

2

. If there 

is no sensor connected, the unit will stop the Quickstart process. In this case, power off, 

connect a sensor and power on again.

Note:

 

1

 Sensor needs to be connected at least.

back (  <-  )     or next   ( -> )

Country selection

Select a country in this menu: 
DE; AT; CH; GB; FR; IT; PL; CZ; DK; SE; BE; RU; NO; LT; SK; NL; FI; IE
back (  <-  )     or next   ( -> )

Date input

Use the +/- button to select the day, month, and year.
back (  <-  )     or next   ( -> )

Time input

Use the +/- button to set the hour and minute.
back (  <-  )     or next   ( -> )

Select heating cable type*

Select the installed pipe freeze protection heating cable:

10

XL

2

-ZH / 

15

XL

2

-ZH / 

26

XL

2

-ZH / 

31

XL

2

-ZH / FS-

10

C-

2

X / Other systems

back (  <-  )     or next   ( -> )

Operation mode*

Select an operation mode:
AMBIENT: Ambient temperature measurement. The operation will be based on PASC 

(Proportional ambient temperature system control).
The unit is working in an energy efficiency mode depending on the outside temperature to 

operate the heating cable based on an internally calculated duty cycle.
LINE : Pipe/line temperature measurement.
Assignment of sensors: Sensor 

1

 for heating circuit 

1

; sensor 

2

 for heating circuit 

2

;   

a revision of this assignment can be done later in the parameter settings.
back (  <-  )     or next   ( -> )

Parameter settings

Default values are set for each parameter. Change the default values by clicking on the 

arrow sign for each value and enter a new value.
back (  <-  )     or next   ( -> )

Pipe diameter*

Select pipe diameter from range DN 

10

 up to DN 

125

.

back (  <-  )

Set min. ambient
temperature*

The minimum ambient temperature is the minimum expected temperature outside 

the building. This parameter influences the duty cycle duration. Use the +/- keys to 

select a temperature. Clicking on the “back” icon ( <- ) will store the value and show it in 

plumbing settings. 
Value Range: From –

40

°C to 

0

°C

back (  <-  )

Set temperature*

Select the temperature using the +/- keys.
The minimum temperature is 

0

°C and max. temperature is +

80

°C

back (  <-  )     

Test program start

YES:

The test program runs for 

30

 minutes, during which all parameters will be ignored to 

check heating cable and connection on site. You can stop the test program at any time.
Quickstart completed -> Main screen

NO:

 Quickstart completed – > Main screen

* Note: 

During Quickstart, the selected parameter is valid for heating circuit (zone) 

1

 and 

2

. An adjustment per heating circuit (zone) 

can be done for each individual heating zone in the parameter setting menu after Quickstart is completed.

ENGLISH

Содержание Elexant 450c

Страница 1: ...Operation Manual Electronic Control Unit For Safe And Efficient Operation Of Pipe Freeze Protection Self Regulating Heating Cable Elektronische Steuereinheit f r einen sicheren und effizienten Betrie...

Страница 2: ...ANT450c ML 2103 TABLE OF CONTENTS PROGRAM START 3 PARAMETER SETTINGS 5 FACTORY SETTINGS DEFAULT 8 ERROR ALARMS AND TROUBLESHOOTING 8 INHALT PROGRAMMSTART 9 SOLLWERTEINGABE 11 WERKSEINSTELLUNGEN STANDA...

Страница 3: ...an internally calculated duty cycle LINE Pipe line temperature measurement Assignment of sensors Sensor 1 for heating circuit 1 sensor 2 for heating circuit 2 a revision of this assignment can be don...

Страница 4: ...CHEM 4 RAYCHEM OM EU1838 ELEXANT450c ML 2103 Main Screen SETTINGS KEYLOCK APPLICATION WARNINGS TIME SET TEMPERATURE HEATING ZONE 1 2 RELAY ON OFF SENSOR NUMBER OPERATION MODE ACTUAL TEMPERATURE APPLIC...

Страница 5: ...ey lock KeyLock Access code 3000 When key lock is On the setup and timer menus are protected by password The unit can be unlocked by entering the pre defined password 3000 After 10 minutes of inactivi...

Страница 6: ...Other system can be used if heating cable type is not known or listed Pipe diameter DN 25 DN 25 Range DN 10 DN 125 Default DN 25 Assign the correct pipe diameter per heating zone 1 and or 2 You can ch...

Страница 7: ...NO FI RU CZ PL SK LT Country Select a country in this menu Your selection defines the default values used for time format pipe diameter and insulation thickness and customer contact data Countries DE...

Страница 8: ...ound OFF Key lock ON ERROR ALARMS AND TROUBLESHOOTING Error Code Elexant 450C Remedy E 2 1 SENSOR_1_OPEN Check sensor connection E 2 2 SENSOR_1_SHORT Check sensor and replace it E 2 3 SENSOR_2_OPEN Ch...

Страница 9: ...nes definierten Arbeitszyklus zu betreiben ROHRF HLER Leitungsrohr Temperaturmessung F hlerzuordnung F hler 1 zu Heizkreis 1 F hler 2 zu Heizkreis 2 Die Zuordnung kann sp ter im Parametrierungsmen ge...

Страница 10: ...M 10 RAYCHEM OM EU1838 ELEXANT450c ML 2103 Hauptbildschirm EINSTELLUNGEN TASTEN SPERRE ANWENDUNG WARNUNGEN ZEIT SOLL TEMPERATUR HEIZZONE 1 2 RELAIS EIN AUS F HLERNUMMER BETRIEBSART AKTUELLE TEMPERATUR...

Страница 11: ...ugangscode 3000 Wenn die Tastensperre auf Ein steht sind die Men s Setup und Timer durch ein Passwort gesch tzt Das Ger t kann durch Eingabe des vordefinierten Passworts 3000 tempor r entsperrt werden...

Страница 12: ...ZH Heizbandreihe 10XL2 ZH 15XL2 ZH 26XL2 ZH 31XL2 ZH FS C10 2X Andere Systeme Standard W hlen Sie den Typ des in Ihrer Installation verwendeten nVent RAYCHEM Heizkabels das an Heizzone 2 angeschlossen...

Страница 13: ...ehler nicht ausgeschaltet Hysterese 2 K 2 K Bereich 1 5 Standard 2 K Hysteresewert kann oberhalb des Sollwerts ver ndert werden ALLGEMEINE EINSTELLUNGEN Sprache W hlen Sie Ihre Sprache aus dem Sprachm...

Страница 14: ...ARME UND FEHLERBEHEBUNG Fehlercode Elexant 450C Fehlerbehebung E 2 1 F hler 1 offen F hlerverbindung pr fen E 2 2 F hler 1 Kurzschluss F hler pr fen und austauschen E 2 3 F hler 2 offen F hlerverbindu...

Страница 15: ...605 01 88 salesee nVent com Italia Tel 39 02 577 61 51 Fax 39 02 577 61 55 28 salesit nVent com Lietuva Latvija Eesti Tel 370 5 2136633 Fax 370 5 2330084 info baltic nVent com Magyarorsz g Tel 36 1 25...

Отзывы: