Страница 1: ...ER XTENDER 12B04A D27 BIDIRECTIONAL L S BAND AMPLIFIER PART NUMBER NW BA 12B04A D27 NuWaves Engineering 132 Edison Drive Middletown Ohio 45044 PH 513 360 0800 FAX 513 539 8782 www nuwaves com product...

Страница 2: ...porated into the chassis Completely Characterized The NuPower Xtender family of solid state bidirectional amplifiers has been completely characterized over temperature voltage and frequency These high...

Страница 3: ...in transmit mode The integrated low noise amplifier provides a minimum of 13 dB of gain in receive mode Based on the latest Gallium Nitride GaN technology NuPower s high efficiency and 6 9 in 3 form f...

Страница 4: ...ansmit RF Gain 15 dB typ Nominal Input Drive Level 27 dBm Maximum Input Drive Level 30 dBm Receive RF Gain 13 dB min Receive Noise Figure 3 5 dB typ T R Mode Automatic Sensing or Manual T R Line T R S...

Страница 5: ...ONS Figure 2 NuPower Xtender 12B04A D27 Mechanical Outline Table 3 NuPower Xtender 12B04A D27 Mechanical Specifications Parameter Specification RF Connectors SMA female Control Power Interface Connect...

Страница 6: ...ratures may require additional heat sinking to maintain a baseplate temperature below 60 C at 100 transmit duty cycle Figure 3 The NuPower PA Kit offers out of the box operation for the user The fan c...

Страница 7: ...Directly connecting to an antenna specified for the frequency range 1 0 to 2 5 GHz Connecting to an inappropriate antenna may result in damage to the amplifier module Connecting to a proper antenna th...

Страница 8: ...into 50 otherwise the amplifier could be damaged 4 1 INTERFACE CONNECTOR The NuPower Xtender features a 9 pin Micro D interface connector for control power and ground connections Table 4 NuPower Xten...

Страница 9: ...r an output source or an input sink When the T R line is configured in source mode the Xtender transmit and receive switching occurs automatically based on the T R level setting and the transceiver s...

Страница 10: ...always ignored After receiving and processing a command the NuPower Xtender sends a Carriage Return terminated string as a notification that the command was completed 5 1 SERIAL COMMANDS Serial comman...

Страница 11: ...recommended to set a lower transmit threshold control value The STAT command can be used to display the current Transmit Threshold Control value The TRLVLxxxx command is used to change the setting of...

Страница 12: ...s controlled by applying a logic high or logic low to this line Applying a logic high signal to this line enables transmit mode while applying a logic low enables receive mode Note Factory default set...

Страница 13: ...disposing of a NuWaves product Do not remove the cover or any hardware Do not remove components from the circuit card assembly Do not incinerate Do not crush or shred Do not dispose of as unsorted mun...

Страница 14: ...and Sales Phone 513 360 0800 Email product sales nuwaves com NuWaves Home Page https www nuwaves com Product Warranty https products nuwaves com wp content uploads NuWaves_Warranty_Repair pdf 7 1 GENE...