RTCINTSTS
– RTC Interrupt Status Register
Register
SFR Address
Reset Value
RTCINTSTS
A7H, Page 3
0000_0000 b
7
6
5
4
3
2
1
0
-
TICKIF
ALMIF
-
R/W
R/W
Bit
Name
Description
[7:2]
-
Reserved.
[1]
TICKIF
RTC Time Tick Interrupt Flag
0 = Tick condition does not occur.
1 = Tick condition occur.
[0]
ALMIF
RTC Alarm Interrupt Flag
0 = Alarm condition is not matched.