NOTE:
Open the DIP switch cover and change the setting of DIP switch.
The cover should be closed after setting DIP switch.
2.4 Setting Dome Camera Address (ID)
To prevent damage, each dome camera must have a unique address (ID).
The factory default setting is 1.
Refer t
o ‘3.11 Dome Communication’ section for detailed information.
2.5 Setting Dome Camera Video Type, Termination & Coaxitron Protocol
You can set video type with D1 and video signal with D2 in SW1.
SW1-D1
Video Type
SW1-D2
RS-485
OFF
HD-TVI OUTPUT
OFF
Terminated
ON
Reserved
ON
Not Terminated
You can set coaxitron protocol with D1 and D2 in SW2.
SW2-D1
SW2-D2
HD-TVI OUTPUT
OFF
OFF
Nuvico-C
ON
OFF
Pelco-C
OFF
ON
Reserved
ON
ON
Reserved